![Flamerite Fires Essence Gotham 1300 Installation, Precautions & Servicing Download Page 4](http://html1.mh-extra.com/html/flamerite-fires/essence-gotham-1300/essence-gotham-1300_installation-precautions-and-servicing_2302469004.webp)
4 |
P a g e
DO NOT TWIST, FORCE OR SQUEEZE THE FIRE DURING THE INSTALLATION PROCESS.
There must be enough clearance for the fire to comfortably fit inside or against a wall. DO NOT SQUEEZE INTO
AN OPENING as this may deform the case and stop the glass from moving correctly.
The height at which you may wish to fix the fire in or on the wall is up to you, we recommend anywhere from
350-450mm from the floor to the bottom of the fire opening (not the bottom of the fire).
The fire must be well supported in or on any structure. A wall support or lintel should be fitted at the required
height to ensure the appliance does not support the weight of the finished wall or chimney breast. Never
secure to just plaster board alone.
1.
Gotham
Secure into place using the fixings provided.
Situ
Screws
Rawl Plugs
Stud Wall
4 x 35mm
N/A
Chimney
4 x 35mm
5.5mm x 34mm
Fireplace
4 x 35mm
5.5mm x 34mm
*Flamerite Suite
4 x 15mm
N/A
The minimum opening size to inset your fire
Model
H
W
D
600
740mm
615mm
180mm
750S
635mm
765mm
180mm
750T
885mm
765mm
180mm
900
510mm
915mm
180mm
1300
510mm
1315mm
180mm
Four larger counter sunk holes will be visible at each corner of the opening to secure your fire.
*(Only, if fitting a Gotham into a Flamerite fireplace suite, this will be done from the back).
Installation Instructions
Please test the fire before permanently boarding, sealing or plastering into place.
Summary of Contents for Essence Gotham 1300
Page 7: ...7 P a g e 750T 750S...
Page 8: ...8 P a g e 900 1300...
Page 13: ...13 P a g e Radia Flame Nitra Flame Wiring Diagrams...