Flamerite Fires Essence Gotham 1300 Installation, Precautions & Servicing Download Page 4

4 | 

P a g e

 

 

 

 

 

 

 

DO NOT TWIST, FORCE OR SQUEEZE THE FIRE DURING THE INSTALLATION PROCESS. 

There must be enough clearance for the fire to comfortably fit inside or against a wall. DO NOT SQUEEZE INTO 

AN OPENING as this may deform the case and stop the glass from moving correctly. 

The height at which you may wish to fix the fire in or on the wall is up to you, we recommend anywhere from 

350-450mm from the floor to the bottom of the fire opening (not the bottom of the fire). 

The fire must be well supported in or on any structure. A wall support or lintel should be fitted at the required 

height to ensure the appliance does not support the weight of the finished wall or chimney breast.  Never 

secure to just plaster board alone. 

1.

 

Gotham 

Secure into place using the fixings provided.   

 

 

 

 

 

 

Situ 

Screws 

Rawl Plugs 

  

 

Stud Wall 

4 x 35mm 

N/A 

  

 

Chimney  

4 x 35mm 

5.5mm x 34mm 

  

 

Fireplace 

4 x 35mm 

5.5mm x 34mm 

  

 

*Flamerite Suite 

4 x 15mm 

N/A 

  

 

The minimum opening size to inset your fire  

 

Model 

600 

740mm 

615mm 

180mm 

750S 

635mm 

765mm 

180mm 

750T 

885mm 

765mm 

180mm 

900 

510mm 

915mm 

180mm 

1300 

510mm 

1315mm 

180mm 

 

Four larger counter sunk holes will be visible at each corner of the opening to secure your fire.   

*(Only, if fitting a Gotham into a Flamerite fireplace suite, this will be done from the back).

 

 

 

Installation Instructions 

 

Please test the fire before permanently boarding, sealing or plastering into place.   

 

Summary of Contents for Essence Gotham 1300

Page 1: ...he fire before removal from the packaging and installation Consider if help is required Always read this manual first before attempting to install or use and keep in a safe place Any alteration to the...

Page 2: ...regulate and clean the appliance or perform user maintenance Some parts of this product can become very hot and cause burns Particular attention must be given where children and vulnerable people are...

Page 3: ...lug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or coloured green or coloured green and yellow or mar...

Page 4: ...ensure the appliance does not support the weight of the finished wall or chimney breast Never secure to just plaster board alone 1 Gotham Secure into place using the fixings provided Situ Screws Rawl...

Page 5: ...Chimney 4 x 35mm 5 5mm x 34mm Fireplace 4 x 35mm 5 5mm x 34mm Suite 4 x 15mm N A The minimum opening size to inset your fire Model H W D 600 725mm 605mm 180mm 900 505mm 920mm 180mm 1300 505mm 1350mm...

Page 6: ...enough room between the front of the logs and the glass channel at the front of the opening so the glass may tilt open freely into the fire and trigger the micro switch Visit www flameritefires com pr...

Page 7: ...7 P a g e 750T 750S...

Page 8: ...8 P a g e 900 1300...

Page 9: ...procedure Make sure the fire is turned off and the heater allowed to cool Insert A Hold the glass panel in each bottom corner B Tilt the top of the glass into the fire C Place the bottom on the glass...

Page 10: ...to use OmniGlide heat and flame enhancement Make sure the glass hits and triggers the internal switch to ready the heat an audible click will be heard The heater will not work if the switch is not tri...

Page 11: ...lamerite service engineer or similarly qualified persons in order to avoid a hazard Please note that replacement lighting is covered by a 2 year warranty Replacements are available from Flamerite Fire...

Page 12: ...room temperature control plus week timer Yes Contact details Flamerite Fires Ltd Greenhough Road Lichfield Staffs WS137AU Nitra Flame Model identifier s 600 900 750 1300 Item 240v 50Hz Symbol Value Va...

Page 13: ...13 P a g e Radia Flame Nitra Flame Wiring Diagrams...