Flamerite Fires Essence Gotham 1300 Installation, Precautions & Servicing Download Page 12

12 | 

P a g e

 

 

 

 

 

 

Information requirement for electric local space heaters

 

Radia Flame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model identifier (s)  

  

  

  

600 

900 

750 

1300 

  

 

 

Item 

@ 240v 

50Hz

 

                         

 

Symbol 

Value 

Value 

Value 

Value 

Unit 

 

 

Heat output 

  

  

  

  

  

  

  

  

  

 

 

Nominal heat output 

 

 

Pnom 

1.5 

1.5 

1.5 

1.5 

kW 

 

 

Minimum heat output (indicative) 

 

Pmin 

0.75 

0.75 

0.75 

0.75 

kW 

 

 

Maximum continuous heat output 

 

Pmax,c 

1.5 

1.5 

1.5 

1.5 

kW 

 

 

Auxiliary electricity consumption 

  

  

  

  

  

  

  

 

 

At nominal heat 

 

 

elmax 

0.033 

0.051 

0.045 

0.063 

kW 

 

 

At minimum heat 

 

 

elmin 

0.033 

0.051 

0.045 

0.063 

kW 

 

 

In standby 

 

 

 

elSB 

0.0005 

0.0005 

0.0005 

0.0005 

kW 

 

 

Type of heat output/room temperature control 

  

  

  

  

  

  

 

 

With distance control option 

  

  

  

  

  

  

  

 

 

Room temperature control, with open window detection 

 

 

 

 

 Yes 

 

 

Adaptive Start 

 

 

 

 

 

 

 

 Yes 

 

 

With electronic room temperature control plus week timer 

  

  

  

Yes 

 

 

Contact details:  

Flamerite Fires Ltd. Greenhough Road, Lichfield.  Staffs. 

  

  

  

 

 

  

  

WS137AU   

 

 

 

 

 

  

 

 

  

  

  

  

  

  

  

  

  

  

 

Nitra Flame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model identifier (s)  

  

  

  

600 

900 

750 

1300 

  

 

 

Item 

@ 240v 

50Hz

 

                         

 

Symbol 

Value 

Value 

Value 

Value 

Unit 

 

 

Heat output 

  

  

  

  

  

  

  

  

  

 

 

Nominal heat output 

 

 

Pnom 

1.5 

1.5 

1.5 

1.5 

kW 

 

 

Minimum heat output (indicative) 

 

Pmin 

0.75 

0.75 

0.75 

0.75 

kW 

 

 

Maximum continuous heat output 

 

Pmax,c 

1.5 

1.5 

1.5 

1.5 

kW 

 

 

Auxiliary electricity consumption 

  

  

  

  

  

  

  

 

 

At nominal heat 

 

 

elmax 

0.027 

0.041 

0.039 

0.051 

kW 

 

 

At minimum heat 

 

 

elmin 

0.027 

0.041 

0.039 

0.051 

kW 

 

 

In standby 

 

 

 

elSB 

0.0005 

0.0005 

0.0005 

0.0005 

kW 

 

 

Type of heat output/room temperature control 

  

  

  

  

  

  

 

 

With distance control option 

  

  

  

  

  

  

  

 

 

Room temperature control, with open window detection 

 

 

 

 

 Yes 

 

 

Adaptive Start 

 

 

 

 

 

 

 

 Yes 

 

 

With electronic room temperature control plus week timer 

  

  

  

Yes 

 

 

Contact details:  

Flamerite Fires Ltd. Greenhough Road, Lichfield.  Staffs. 

  

  

  

 

 

  

  

WS137AU   

 

 

 

 

 

  

 

 

  

  

  

  

  

  

  

  

  

  

 

 

 

 

Information Requirements 

 

 

 

 

 

 

Summary of Contents for Essence Gotham 1300

Page 1: ...he fire before removal from the packaging and installation Consider if help is required Always read this manual first before attempting to install or use and keep in a safe place Any alteration to the...

Page 2: ...regulate and clean the appliance or perform user maintenance Some parts of this product can become very hot and cause burns Particular attention must be given where children and vulnerable people are...

Page 3: ...lug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or coloured green or coloured green and yellow or mar...

Page 4: ...ensure the appliance does not support the weight of the finished wall or chimney breast Never secure to just plaster board alone 1 Gotham Secure into place using the fixings provided Situ Screws Rawl...

Page 5: ...Chimney 4 x 35mm 5 5mm x 34mm Fireplace 4 x 35mm 5 5mm x 34mm Suite 4 x 15mm N A The minimum opening size to inset your fire Model H W D 600 725mm 605mm 180mm 900 505mm 920mm 180mm 1300 505mm 1350mm...

Page 6: ...enough room between the front of the logs and the glass channel at the front of the opening so the glass may tilt open freely into the fire and trigger the micro switch Visit www flameritefires com pr...

Page 7: ...7 P a g e 750T 750S...

Page 8: ...8 P a g e 900 1300...

Page 9: ...procedure Make sure the fire is turned off and the heater allowed to cool Insert A Hold the glass panel in each bottom corner B Tilt the top of the glass into the fire C Place the bottom on the glass...

Page 10: ...to use OmniGlide heat and flame enhancement Make sure the glass hits and triggers the internal switch to ready the heat an audible click will be heard The heater will not work if the switch is not tri...

Page 11: ...lamerite service engineer or similarly qualified persons in order to avoid a hazard Please note that replacement lighting is covered by a 2 year warranty Replacements are available from Flamerite Fire...

Page 12: ...room temperature control plus week timer Yes Contact details Flamerite Fires Ltd Greenhough Road Lichfield Staffs WS137AU Nitra Flame Model identifier s 600 900 750 1300 Item 240v 50Hz Symbol Value Va...

Page 13: ...13 P a g e Radia Flame Nitra Flame Wiring Diagrams...

Reviews: