All track data can be stored in internal non-volatil memory and will be reloaded after power on.
Set all three tracks to mode KNOB (all LED’s off) and then push the button SAVE. Now you store
all the recorded data (all LED’s are blinking). LED’s off displays the end of the storage.
Just as well you can store the tracks separately: while hold down button SAVE press the REC
button of the track for save this selected track.
ADVICE:
The storage can take a long time (max. 85 seconds) depending on the different lenght of the
recorded tracks. The loading time (after power on) increases as well with the lenght of the recor-
ded tracks (max 25 seconds).
3.6 Save recorded data
You can make a prospective firmware update/upgrade via USB.
Where required you find further informations on our website.
3.8 Firmware updates
Turning on the module the internal data can be reset to the factory settings. For this purpose
push the button KNOB of track 1 while power on until all three yellow LED’s turn on (after the
LED sequence). Then let loose the button. This procedure set the tracks to zero.
3.7 Initialization (Setting on factory defaults)
7