1. Short description
2. Hardware / Connections
The C3 module is a three-channel module for recording and playing back movements of con-
trollers. Those can be recorded with each channel´s individual knob. The movements will be out-
put as control voltages.
The record time amounts to 102 seconds maximal.
The track can be played once only (one shot) or in loop. The speed of the play back or the out-
put offset is controllable with the pot.
Track one has an additional CV input. The pot 1 can be used here like an offset ruler.
All three tracks have a common reset input. All track data can be stored in internal non-volatil
memory and will be reloaded after power on.
Software updates are possible via backward USB connector.
3
2.1 Connection to the modular system
(Doepfer bus)
The module is delivered with a connected
ribbon cable for the Doepfer bus. The red
lead marks -12 volt. Connecting the module
please note the right polarity!
If the module is poled accidentally wrong
safety diodes avoid the immediate destruc-
tion of the module but further damages can-
not be excepted.
So please pay attention: Check the connec-
tion various times before switching on!
-12V
Ground Ground Ground
+12V