If the pressure switch does not work
(
overpressure
), the safety valve will auto-
matically operate and open when the pres-
sure exceeds the max. setted value.
I
WARNING!
Compressors must be connected to an
outlet protected by a suitable magne-
to-thermic switch.
The tabs show the absorption data for each
type of compressor:
Motor type
33
Motor type
66
Motor type
99
230 V
50 Hz
115 V
60 Hz
230 V
50 Hz
115 V
60 Hz
230 V
50 Hz
115 V
60 Hz
2,4A
4,8A
4,8A
9,6 A
7,2 A
14,4 A
The compressor feeding lines or eventual
extensions must have the wire section pro-
portioned to the lenght.
The tables show the wires section data for
each type of compressor in relation to the
lenght:
to 3 m.
from 3
to 20 m.
230 V
50 Hz
115 V
60 Hz
230 V
50 Hz
115 V
60 Hz
Motor
type 33
1 mm
2
2
1,5 mm2
2
1,5 mm2
2
2,5 mm2
2
Motor
type 66
1,5 mm2
2
2,5 mm2 1,5 mm2
2
2,5 mm2
Motor
type 99
1,5 mm2
2
2,5 mm2
2
2,5 mm2
2
2,5 mm2
2
Hvis pressostaten ikke virker (
overtryk
),
aktiveres sikkerhedsventilen automatisk og
åbnes, når trykket overstiger den indstillede
maksimumværdi.
I
Advarsel!
Kompressorerne skal tilsluttes en ud-
gang, der er beskyttet af en magneto-ter-
misk kontakt.
Tabellerne viser ampereforbrug for hver
enkelt kompressortype:
Motor type
33
Motor type
66
Motor type
99
230 V
50 Hz
115 V
60 Hz
230 V
50 Hz
115 V
60 Hz
230 V
50 Hz
115 V
60 Hz
2,4A
4,8A
4,8A
9,6 A
7,2 A
14,4 A
Kompressorens arbejdsledninger eller even-
tuelle forlængerledninger skal dimensione-
res i forhold til deres længde.
Tabellerne viser dimensionering af ledninger
for hver enkelt kompressortype i forhold til
deres længde:
Indtil 3 m
Fra 3
til 20 m
230 V
50 Hz
115 V
60 Hz
230 V
50 Hz
115 V
60 Hz
Motor
type 33
1 mm2
2
1,5 mm2
2
1,5 mm2
2
2,5 mm2
2
Motor
type 66
1,5 mm2
2
2,5 mm2
2
1,5 mm2
2
2,5 mm2
2
Motor
type 99
1,5 mm2
2
2,5 mm2
2
2,5 mm2
2
2,5 mm2
2
11