Introduction

You have just received an FLE-150RC 150kW Electric Construction Heater manufactured by Flagro.

Use:

 The FLE-150RC Electric Construction Heater is designed for temporary heat only. 

The heater is to be installed indoors 
The FLE-150RC is designed to heat large spaces, buildings
and machines without worrying about on site fuel.

Quality

: The FLE-150RC is built with the highest quality of components, giving our

customers the confidence they deserve in a Flagro product. 

Convenience:

 The FLE-150RC gives our customers the flexibilty of a 60kW/90kW/150kW heat setting.

The heater is equipped with a; fan speed inverter control that provides optimum temperature rise
by adjusting blower output at each heat setting.  Colour coded Cam Lock power connections
for easy installation. Remote thermostat option available.

Inlet Duct Adapter

The FLE-150RC  includes a permanant inlet duct adapter.

Safety

Always verify that you have proper voltage supply. (575V) It is important to check
the wiring connections inside the heater before plugging in the Cam Locks.
Use a meter to measure volt supply to each cam lock.
Work on the internal systems should only be attempted by a certified electrician and
only when power has been disconnected and can not be reconnected to the heater.

Grounding

The heater is supplier with a cam lock system with a grounding connection and is indicated with a "G" 
on the cam lock panel.  The heater is also supplied with a grounding nuts found on all panels.
It is very important to double check that all grounding connections are properly secure.

Clearance from Combustibles

The discharge temperature of these units may reach very high temperatures.  Maintain minimum 
distance from combustible materials as follows:

Top: 6 Inches
Bottom: 6 Inches
Sides: 6 Inches
Discharge: 15 FT

Summary of Contents for FLE-150RC

Page 1: ...0RC 575V INDUSTRIAL COMMERCIAL ELECTRIC HEATER OPERATOR MUST RETAIN FOR FUTURE REFERENCE Suitable for indoor installation only Unvented Unattended Type 26 Benfield Drive St Catharines Ontario Canada L...

Page 2: ...USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID C...

Page 3: ...stat option available Inlet Duct Adapter The FLE 150RC includes a permanant inlet duct adapter Safety Always verify that you have proper voltage supply 575V It is important to check the wiring connect...

Page 4: ...embly and ensure the motor and blade are operating properly 4 Compressed air may be used to keep components free of dust and dirt build up Pre Start Checklist 1 Heater must be level and lockable wheel...

Page 5: ...ower supply 5 Pull Master button to the out position 6 Determine Manual or Remote Thermostat if remote set desired temperature 7 Turn Blower on off switch to the ON position The blower will start and...

Page 6: ...0 7300 120F 83 DB 90 kW 307 000 6700 88F 81 DB 60kW 205 000 5400 56F 76 DB FAN ONLY 7900 N A 85 DB SHUTDOWN 1 Move all heat control setting to the OFF position 2 Leave Fan in the ON position for 3 5 m...

Page 7: ...RISE above ambient 60KW 56 F 90KW 88 F 150 KW 120 F AMP DRAW MOTOR 5 AMPS 60KW 54 AMPS 90KW 81 AMPS 150KW 136 AMPS DB noise level FAN ONLY 85 60KW 76 90KW 81 150KW 83 INLET SIZE no ducting 20 Dia OUTL...

Page 8: ...E 150RC 90 KW 50 Hz 4650 CFM FLE 150RC 150 KW 55 Hz 5300 CFM FLE 150RC FAN ONLY 60 Hz 7900 CFM THE VFD HAS BEEN PASSWORD PROTECTED WITH THE PREPROGAMMED SETTINGS THESE SETTINGS ARE THE MINIMUM AIR FLO...

Page 9: ...CE OF WARNING OR FAULT MESSAGES THAT MAY APPEAR ON THE SCREEN OF THE VFD IF ANY OF THE MESSAGE DO APPEAR PLEASE REVIEW THE VFD MANUAL OR CONTACT FLAGRO INDUSTRIES TO HELP CORRECT THE ISSUE TO REVIEW F...

Page 10: ...VARIABLE FREQUENCY DRIVE STATUS WARNING MESSAGES...

Page 11: ......

Page 12: ...VARIABLE FREQUENCY DRIVE FAULT MESSAGES...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...UT POWER ON TRANSFORMER SHOULD BE 120 VOLTS IF NO POWER TURN POWER OFF AND CHECK FU1 5A FUSE IF GOOD CHECK FB4 5 A FUSES FOR CONTINUITY IF TRANSFORMER HAS PROPER OUTPUT POWER CHECK VFD SCREEN FOR COMM...

Page 17: ...O DETERMINE IF FAULTY SHUT POWER OFF BYPASS SWITCH THEN TURN POWER ON FOR TEST INSPECT INTAKE AIR FILTER S CLEAN IF REQUIRED UNIT PROVES AIR BLOWER RUNS BUT HEAT WILL NOT ENGAGE CHECK OHMS RESISTANCE...

Page 18: ...TACT BLOCK BEHIND HEATER SWITCH RED WIRE PERFORM OHM RESISTANCE TEST BYPASS HIGH LIMIT OR AIR PRESSURE SWITCH IF ELEMENT STILL DOES NOT ENGAGE RUN JUMPER WIRE FROM TB3 TO TB10 IF ELEMENT WORKS PROBLEM...

Page 19: ...CK FUSES TO THE CONTACTOR THAT IS NOT WORKING PROPERLY DO OHM TEST OF ELEMENT EACH SIDE TEST SEPARATE FLE 60 20KW 40KW FLE 150RC 60KW 90KW PLEASE SEE CHART BELOW FOR READINGS TEST OHM READING FLE 150R...

Page 20: ...PEED DRIVE 7 5 HP MOTOR FLE 1503A 575VOLT FLE 1504A 575 VOLT FUSES FLE 1509 125 Amp Class T FLE 1510A 80 Amp Class T FLE 1511B 12 Amp Class CC FLE 631 Amp Class CC FLE 1515 2 Amp AGC Glass TRANSFORMER...

Page 21: ...POSITION SWITCH FLE 633 60KW 90KW THERMOSTAT MANUAL BLOWER ON OFF EMERGENCY STOP BUTTON FLE 634 GREEN AIR PROVEN LIGHT FLE 636 FLE 635 HIGH LIMIT AIR PROVEN LIGHT THERMOSTAT FV 414B N C CONTACT BLOCK...

Page 22: ...OCKABLE FLE 610 6 RIGID FLE 611 BLUE FLE 612 BLACK FLE 613 GREEN FLE 614 RED CAM LOCK PANEL CAM LOCK DETACHABLE FLE 615 BLUE FLE 616 BLACK FLE 617 GREEN FLE 618 RED SNAP COVERS PANEL FLE 611A BLUE FLE...

Page 23: ...12 AMP CLASS CC TIME DELAY FUSE THREE PER HEATER FLE 1512 AIR PROVING SWITCH COMPLETE FLE 1513 OUTLET HIGH LIMIT 250F FLE 1514 INLET GUARD PRIOR TO 2018 FLE 1515 2 AMP FUSE FLE 609 6 LOCKABLE SWIVEL...

Page 24: ...ODULE ONLY FLE 635B RED HIGH LIMIT NON PROVEN AIR LIGHT LED COMPLETE FLE 636 GREEN AIR PROVEN LIGHT LENS ONLY FLE 636A GREEN AIR PROVEN LIGHT LED MODULE ONLY FLE 636B GREEN AIR PROVEN LIGHT LED COMPLE...

Page 25: ...W BC L2 L3 3L1 BK 14 AWG 12 TEW BC 3L2 3L3 FB3 12 A FB4 0 5A U1 V1 W1 PE 7 5 HP FLA 7 A 3 M T1 T2 T3 PE GB Ground Bar PE 2A FU1 TB 2 GB Ground Bar L1 BK 2 AWG 16 T90 THHN 1R1 BK 6 AWG 45 SEW 2 2L1 BK...

Reviews: