Flagro FLE-150RC Operating Instructions Manual Download Page 25

0100

0101

0102

0103

0104

0105

0106

0107

0108

0109

0110

0111

0112

0113

0114

0115

0116

0117

0118

0119

0120

0121

0122

0123

0124

0125

0126

0127

0128

0129

0130

0131

0132

0133

0134

0135

0136

0137

0138

0139

0140

0141

0142

0143

0144

0145

0146

0147

0148

0149

0150

0151

0152

0153

0154

0155

0156

0157

0158

0159

Description

254XXX

Date

FLE-1505A HEATER CONTROL PANEL

Modification

Name

Job Number

4875 KENT AVENUE
NIAGARA FALLS
ONTARIO  L2H 1J1
CANADA
t:  +1.905.295.2525
f:  +1.905.295.2528
http://www.PowerUnderControl.com

2016/09/06

DM

2019/04/11

DM

2019/04/11

Rev.

Date

Date

Date

Creator

Checked

Approved

Page

01

Of

MPNL

05

Designation

THIS DRAWING & DESIGN ARE PROPRIETARY TO SYNCHRO

ENGINEERING LIMITED ALL RIGHTS RESERVED. NEITHER THE

DRAWING OR DESIGN MAY BE COPIED OR OTHERWISE

DISSEMINATED IN ANY MANNER OR FORM, IN WHOLE OR IN PART,

WITHOUT, IN EACH INSTANCE, THE PRIOR WRITTEN CONSENT OF

SYNCHRO ENGINEERING LIMITED.  THESE DRAWINGS ARE

PROTECTED BY CANADIAN AND UNITED STATES COPYRIGHT LAW. 

UNAUTHORIZED REPRODUCTION OF THESE DRAWINGS IS
PROHIBITED.  (C) SYNCHRO ENGINEERING LIMITED 2016.

KE

150 KW

575 VAC

3 PHASE 

60 HZ

NOTE: #16 AWG CONTROL WIRING TO BE TEW BC

2

VFD

(0154)

L1

L2

L3

T1

PE

PE

T2

T3

1

2

(0145)

C1

3

4

5

6

1

2

(0147)

C2

3

4

5

6

C60

A60

B60

C90

B90

A90

-T1

H2

150VA 575V/120V

X1

X2

H1

PB1

MASTER PULL

ON

(0153)

TB

3

TB

3

TB

3

PS1

AIR FLOW

11

12

R1

(0131)

11

12

R2

(0139)

TB

5

A1

A2

R1

(0135)
(0141)

TB

X2

TB
X2

G

PL1

AIRFLOW PROVEN

TB

5

R

PL2

AIRFLOW NOT

PROVEN

R

PL3

OVERTEMP

2

BK

14 AWG

22''

SEW-2

3

BK

14 AWG

22''

SEW-2

TB

6

TB

7

TB

3

TS1

OVERTEMP

TB

8

A1

A2

R2

(0137)
(0141)

TB

X2

21

24

R1

(0131)

21

24

R2

(0139)

TB

10

OFF

ON

SS2

BLOWER

MANUAL

REMOTE

SS1

OFF

ON

SS3

60KW

A1

A2

C1

(0100)
(0101)
(0102)

TS2

REMOTE

OVERTEMP

OFF

ON

SS4

90KW

TB
13

TB
14

A1

A2

C2

(0107)
(0108)
(0109)

TB
X2

VFD

(0113)

VFD CONTROL CIRCUIT CONNECTIONS

1

4

13B

13A

YE
13

+LOT1 (Operator Panel)

+LOT1 (Operator Panel)

L1

BK

10 AWG

16''

TEW BC

L2

L3

3L1

BK

14 AWG

12''

TEW BC

3L2

3L3

FB3

12 A

FB4

0.5A

U1

V1

W1

PE

7.5 HP
FLA = 7 A

3

M

T1

T2

T3

PE

GB

Ground Bar

PE

2A

FU1

TB

2

GB

Ground Bar

L1

BK

2 AWG

16''

T90/THHN

1R1

BK

6 AWG

45''

SEW-2

2L1

BK

2 AWG

8''

TEW BC

2L2

2L3

2R1

BK

2 AWG

33''

SEW-2

FB1

80 A

FB2

125 A

3

RD

16 AWG

28''

TEW BC

4

RD

16 AWG

28''

TEW BC

5

RD

16 AWG

28''

TEW BC

X2

WH

16 AWG

28''

TEW BC

X2

WH

16 AWG

4.75''

TEW BC

X2

WH

16 AWG

11.25''

TEW BC

8A

RD

16 AWG

28''

TEW BC

8

RD

16 AWG

13.5''

TEW BC

8

RD

16 AWG

3.5''

TEW BC

9A

RD

16 AWG

5.5''

TEW BC

9

RD

16 AWG

4.75''

TEW BC

9

RD

16 AWG

5.5''

TEW BC

9

RD

16 AWG

4.75''

TEW BC

11

RD

16 AWG

28''

TEW BC

10

RD

16 AWG

28''

TEW BC

12

YE

16 AWG

8''

TEW BC

13A

YE

16 AWG

28''

TEW BC

13B

YE

16 AWG

28''

TEW BC

12

YE

16 AWG

8''

TEW BC

12

YE

16 AWG

12''

TEW BC

13

YE

16 AWG

28''

TEW BC

12A

YE

16 AWG

28''

TEW BC

2

RD

16 AWG

28''

TEW BC

1

RD

16 AWG

28''

TEW BC

L2

L3

L1

BK

2 AWG

15''

T90/THHN

L2

L3

L2

BK

10 AWG

4''

TEW BC

L1

BK

10 AWG

4''

TEW BC

L1

BK

6 AWG

10''

TEW BC

L2

L3

H2

BK

14 AWG

22''

TEW BC

H1

BK

14 AWG

22''

TEW BC

X1

RD

14 AWG

6''

TEW BC

1

RD

14 AWG

12''

TEW BC

1

RD

14 AWG

23''

TEW BC

2

RD

16 AWG

23''

TEW BC

3

RD

16 AWG

23''

TEW BC

4

RD

16 AWG

23''

TEW BC

5

RD

16 AWG

23''

TEW BC

8A

RD

16 AWG

23''

TEW BC

10

RD

16 AWG

23''

TEW BC

11

RD

16 AWG

23''

TEW BC

6

BK

14 AWG

24''

SEW-2

2

BK

14 AWG

24''

SEW-2

13

YE

16 AWG

39''

TEW BC

13B

YE

16 AWG

39''

TEW BC

13A

YE

16 AWG

39''

TEW BC

12A

YE

16 AWG

39''

TEW BC

2

RD

16 AWG

18''

TEW BC

3

RD

16 AWG

18''

TEW BC

7

RD

16 AWG

17''

TEW BC

6

RD

16 AWG

12''

TEW BC

3

RD

16 AWG

12''

TEW BC

2

RD

16 AWG

12''

TEW BC

2

RD

16 AWG

12''

TEW BC

2

RD

16 AWG

12''

TEW BC

10

RD

16 AWG

31''

TEW BC

11

RD

16 AWG

36''

TEW BC

4

RD

16 AWG

23''

TEW BC

5

RD

16 AWG

23''

TEW BC

8A

RD

16 AWG

23''

TEW BC

GN

14 AWG

39''

TEW BC

X2

WH

16 AWG

15''

TEW BC

X2

WH

16 AWG

23''

TEW BC

X2

WH

16 AWG

12''

TEW BC

X2

WH

16 AWG

33''

TEW BC

X2

WH

16 AWG

15''

TEW BC

X2

WH

16 AWG

21''

TEW BC

1

J1 P1

1

P1

2

J1

2

1

J4 P4

1

P4

2

J4

2

3

J1 P1

3

4

J1 P1

4

5

J1 P1

5

P1

9

J1

9

1

J5 P5

1

P5

2

J5

2

6

J1 P1

6

1

J2 P2

1

P2

2

J2

2

P1

7

J1

7

P1

8

J1

8

P3

3

J3

3

P3

4

J3

4

P3

2

J3

2

1

J3 P3

1

1R2

50''

1R3

57''

2R2

41''

2R3

49''

0120

(.0120)

0124

(.0124)

0120 (.0130)

0124 (.0130)

L1

L2

L3

GND

Summary of Contents for FLE-150RC

Page 1: ...0RC 575V INDUSTRIAL COMMERCIAL ELECTRIC HEATER OPERATOR MUST RETAIN FOR FUTURE REFERENCE Suitable for indoor installation only Unvented Unattended Type 26 Benfield Drive St Catharines Ontario Canada L...

Page 2: ...USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABEL ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID C...

Page 3: ...stat option available Inlet Duct Adapter The FLE 150RC includes a permanant inlet duct adapter Safety Always verify that you have proper voltage supply 575V It is important to check the wiring connect...

Page 4: ...embly and ensure the motor and blade are operating properly 4 Compressed air may be used to keep components free of dust and dirt build up Pre Start Checklist 1 Heater must be level and lockable wheel...

Page 5: ...ower supply 5 Pull Master button to the out position 6 Determine Manual or Remote Thermostat if remote set desired temperature 7 Turn Blower on off switch to the ON position The blower will start and...

Page 6: ...0 7300 120F 83 DB 90 kW 307 000 6700 88F 81 DB 60kW 205 000 5400 56F 76 DB FAN ONLY 7900 N A 85 DB SHUTDOWN 1 Move all heat control setting to the OFF position 2 Leave Fan in the ON position for 3 5 m...

Page 7: ...RISE above ambient 60KW 56 F 90KW 88 F 150 KW 120 F AMP DRAW MOTOR 5 AMPS 60KW 54 AMPS 90KW 81 AMPS 150KW 136 AMPS DB noise level FAN ONLY 85 60KW 76 90KW 81 150KW 83 INLET SIZE no ducting 20 Dia OUTL...

Page 8: ...E 150RC 90 KW 50 Hz 4650 CFM FLE 150RC 150 KW 55 Hz 5300 CFM FLE 150RC FAN ONLY 60 Hz 7900 CFM THE VFD HAS BEEN PASSWORD PROTECTED WITH THE PREPROGAMMED SETTINGS THESE SETTINGS ARE THE MINIMUM AIR FLO...

Page 9: ...CE OF WARNING OR FAULT MESSAGES THAT MAY APPEAR ON THE SCREEN OF THE VFD IF ANY OF THE MESSAGE DO APPEAR PLEASE REVIEW THE VFD MANUAL OR CONTACT FLAGRO INDUSTRIES TO HELP CORRECT THE ISSUE TO REVIEW F...

Page 10: ...VARIABLE FREQUENCY DRIVE STATUS WARNING MESSAGES...

Page 11: ......

Page 12: ...VARIABLE FREQUENCY DRIVE FAULT MESSAGES...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...UT POWER ON TRANSFORMER SHOULD BE 120 VOLTS IF NO POWER TURN POWER OFF AND CHECK FU1 5A FUSE IF GOOD CHECK FB4 5 A FUSES FOR CONTINUITY IF TRANSFORMER HAS PROPER OUTPUT POWER CHECK VFD SCREEN FOR COMM...

Page 17: ...O DETERMINE IF FAULTY SHUT POWER OFF BYPASS SWITCH THEN TURN POWER ON FOR TEST INSPECT INTAKE AIR FILTER S CLEAN IF REQUIRED UNIT PROVES AIR BLOWER RUNS BUT HEAT WILL NOT ENGAGE CHECK OHMS RESISTANCE...

Page 18: ...TACT BLOCK BEHIND HEATER SWITCH RED WIRE PERFORM OHM RESISTANCE TEST BYPASS HIGH LIMIT OR AIR PRESSURE SWITCH IF ELEMENT STILL DOES NOT ENGAGE RUN JUMPER WIRE FROM TB3 TO TB10 IF ELEMENT WORKS PROBLEM...

Page 19: ...CK FUSES TO THE CONTACTOR THAT IS NOT WORKING PROPERLY DO OHM TEST OF ELEMENT EACH SIDE TEST SEPARATE FLE 60 20KW 40KW FLE 150RC 60KW 90KW PLEASE SEE CHART BELOW FOR READINGS TEST OHM READING FLE 150R...

Page 20: ...PEED DRIVE 7 5 HP MOTOR FLE 1503A 575VOLT FLE 1504A 575 VOLT FUSES FLE 1509 125 Amp Class T FLE 1510A 80 Amp Class T FLE 1511B 12 Amp Class CC FLE 631 Amp Class CC FLE 1515 2 Amp AGC Glass TRANSFORMER...

Page 21: ...POSITION SWITCH FLE 633 60KW 90KW THERMOSTAT MANUAL BLOWER ON OFF EMERGENCY STOP BUTTON FLE 634 GREEN AIR PROVEN LIGHT FLE 636 FLE 635 HIGH LIMIT AIR PROVEN LIGHT THERMOSTAT FV 414B N C CONTACT BLOCK...

Page 22: ...OCKABLE FLE 610 6 RIGID FLE 611 BLUE FLE 612 BLACK FLE 613 GREEN FLE 614 RED CAM LOCK PANEL CAM LOCK DETACHABLE FLE 615 BLUE FLE 616 BLACK FLE 617 GREEN FLE 618 RED SNAP COVERS PANEL FLE 611A BLUE FLE...

Page 23: ...12 AMP CLASS CC TIME DELAY FUSE THREE PER HEATER FLE 1512 AIR PROVING SWITCH COMPLETE FLE 1513 OUTLET HIGH LIMIT 250F FLE 1514 INLET GUARD PRIOR TO 2018 FLE 1515 2 AMP FUSE FLE 609 6 LOCKABLE SWIVEL...

Page 24: ...ODULE ONLY FLE 635B RED HIGH LIMIT NON PROVEN AIR LIGHT LED COMPLETE FLE 636 GREEN AIR PROVEN LIGHT LENS ONLY FLE 636A GREEN AIR PROVEN LIGHT LED MODULE ONLY FLE 636B GREEN AIR PROVEN LIGHT LED COMPLE...

Page 25: ...W BC L2 L3 3L1 BK 14 AWG 12 TEW BC 3L2 3L3 FB3 12 A FB4 0 5A U1 V1 W1 PE 7 5 HP FLA 7 A 3 M T1 T2 T3 PE GB Ground Bar PE 2A FU1 TB 2 GB Ground Bar L1 BK 2 AWG 16 T90 THHN 1R1 BK 6 AWG 45 SEW 2 2L1 BK...