3
FORCE PLATE 1000 Kg
Capacity
FORCE PLATE 400 Kg Capacity
Fitness Technology, 21 Bishop Street, Skye SA 5072 Australia
Postal Address: PO Box 139 Fullarton 5063 Tel: +61 8 8331 9229 Mob: 0418 815 400.
www.fittech.com.au
Copy
right: Fitness Technology, Adelaide, Australia 3rd Feb 2020 Issue 1.00, 3rd Feb 2020
Page | 3
PCB:
Self-contained in the 400S Platform Assembly.
Load Cell Wiring
The four Load Cells connect into the XPV7 Electronics Module are colour coded on the
load cell cables at the terminal blocks for ease of wiring, they are as follows
Load Cell
1.
Blue
Heat - Shrink shroud as per next page
Load Cell
2.
Green
Heat - Shrink shroud as per next page
Load Cell
3.
Red
Heat - Shrink shroud as per next page
Load Cell
4.
Yellow
Heat - Shrink shroud as per next page
The wiring connection for each individual load cell is as follows.
Ex+ RED
Terminal
Block is not
Sig + White
on 400 S Plate
Sig - Green
Ex- Black
Shield (Heat shrink - wire colour may vary)