FORCE PLATE 1000 Kg 

 Capacity

 

                                                                        

FORCE PLATE 400 Kg Capacity 

 

Fitness Technology, 21 Bishop Street, Skye SA 5072 Australia 

Postal Address: PO Box 139 Fullarton 5063 Tel:  +61 8 8331 9229    Mob: 0418 815 400.     

www.fittech.com.au

 

[email protected] 

Copy

right:   Fitness Technology, Adelaide, Australia 3rd Feb 2020 Issue 1.00, 3rd Feb 2020   

Page | 2 

 
Specifications. 

 

Capacity:

          1000Kg Rated Force  

 

Safety Factor:

  Side-load rejection ratio 500:1  

 

Safe side-load 100 % of R.C. Maximum safe central overload 150 % of R.C.  

 

Ultimate central overload 300 % of R.C. 

 

Physical Size:

  795mm x 795mm x 60mm  

 

Materials:

         Carbon Fibre Platform with non-slip Top.  

                          Load Cells complete with adjustable height feet assemblies that can adjust the height of the 

Plate to approx 120mm   

 

Sample Rate:

   Maximum Sampling Rate of 1000Hz on all channels via BMS version 2 (BMSv2) software 

program. 

 

Integration:

      400S+ Performance Force Plate + BMS Linear Position Transducer (LPT) is calibrated by 

users on site via the BMSv2 software via Tools\Configure\Calibration (tab window)  

 

Unique:

            Only Performance Force Plate on the market with a footprint size large enough for every 

users’ Centre of Mass (COM) to remain over this force plate for all testing functions for 
accurate data collection all the time.   It is also capable of running the BMS LPT & auto 
saving all data files + outputting to Excel via the BMS software. It also measures uni-lateral & 
bilateral R & L leg anterior / posterior & medio / lateral force - all done on this single 400S+ 
force plate! 

 

Only Performance Force Plate on the market capable of running on our new InnerBalance 
software tracking used to measure & record all anterior-posterior & mediolateral sway 
movements.   

 

Weight:

             400S+, 14.5 Kg (32 lbs)  

 

Operation:

       Integral PCB Module operates 4 Load Cells + Output powered via 5 V DC Computer USB 

Port only. Sensor type Steel Shear Beams rating 250Kg @ 3mV/V that are genuinely rated 
to sample @ 1000Hz. Simply install the software onto your Hard Drive and then connect the 
USB Cable plug into your Computer. The 400S requires no other power supply or charging 
of batteries is required.   

 

PCB monitors:

 Sensors # 1 

– 4 each have a Load cell cable connector 5 terminal plug (Molex) (four in total 

as shown on pages 3&4) sensors # 1&2, 3&4 may share a Load cell cable connector 10 
terminal plug (Molex) (two in total as shown on page 14). These connect to 4 Load cells. 
(see page 6).  

 

Outputs:

  

Communicates via 1 x USB 2.0 Cable that does not rely on Bluetooth or other wireless 

connection to the laptop, so has NO internal batteries - annoying flat battery and recharging 

issues are irrelevant!   

Power:

              Computer USB supplies 100% of power supply to operate the 400S from any PC or laptop 

USB Port. 1 

 

Cables:

             1 x USB 2.0 Extension Cable 3 M Long provided with all 400S units. This mean zero 

external RF interference.  

 

Connections:

  1 x RJ 45 Connection (located under the Force Plate) with connection lead supplied going to 

1K Ohm Potentiometer on the BMS LPT Model

 

PT5A-150-V62-UP-1K-M6-632676A

 

this 

LPT is an optional plug-in connection 

– only used if barbell tracking data is also required to 

be tracked simultaneously with the ground reaction force data (See pages 4 & 5).  

Summary of Contents for 400S+

Page 1: ...ave any questions about this product Fitness Technology 21 Bishop St Skye SA 5072 Australia Postal Address PO Box 139 Fullarton 5063 61 418815400 Mob 0418 815 400 www fittech com au E info fittech com au Copyright Fitness Technology Adelaide Australia 03 February 2020 FORCE PLATE 400S Performance Force Plate Manual ...

Page 2: ...lia 3rd Feb 2020 Issue 1 00 3rd Feb 2020 Contents Specifications 2 Load Cell Wiring 3 Installation 4 USB and PT5A position Transducer Cable Connections 4 Installation of 4 x Platform Feet 6 Levelling the 400S Performance Force Plate 6 Care and Maintenance of Force Plate 7 PRECAUTIONS 7 Warranty 7 Frequently Asked Questions 8 Q How do you calculate your variables 8 Q What is the sampling period for...

Page 3: ...0S force plate Only Performance Force Plate on the market capable of running on our new InnerBalance software tracking used to measure record all anterior posterior mediolateral sway movements Weight 400S 14 5 Kg 32 lbs Operation Integral PCB Module operates 4 Load Cells Output powered via 5 V DC Computer USB Port only Sensor type Steel Shear Beams rating 250Kg 3mV V that are genuinely rated to sa...

Page 4: ...oad Cell Wiring The four Load Cells connect into the XPV7 Electronics Module are colour coded on the load cell cables at the terminal blocks for ease of wiring they are as follows Load Cell 1 Blue Heat Shrink shroud as per next page Load Cell 2 Green Heat Shrink shroud as per next page Load Cell 3 Red Heat Shrink shroud as per next page Load Cell 4 Yellow Heat Shrink shroud as per next page The wi...

Page 5: ...form by rotating the feet to the right right hand thread Adjust height as show below 4 Connect the USB communication cable as shown below by removing the plug allowing access to the communications port See photos below 5 The Platform is now ready for use 6 Install the communications software and the processing software following the instruction for each module 7 The XPV7 PCB Electronics Module wil...

Page 6: ...m au Copyright Fitness Technology Adelaide Australia 3rd Feb 2020 Issue 1 00 3rd Feb 2020 In the image above you can see the USB connector for the Force plate and the cat5e connector for the LPT Both are tucked back in under the rear cover for shipping See below for an example of the PT5A position transducer connected to the 400S Performance force plate USB Connector Cat5e Lead connects to RJ45 So...

Page 7: ...tch threads are installed in each of the four corners They screw into the Platform with standard a right hand thread Stainless Steel M12 spacer Nuts are used for levelling and adjusting the height of the Platform If required the M12 spacer nuts can be removed but if this is done never thread the 4 x feet threads thru all the way back off 5mm See page 11 for more detail Levelling the 400S Performan...

Page 8: ...ny part that is proved to be defective due to faulty workmanship Defects or failures in equipment which under proper use appear therein and arise solely from faulty materials or workmanship will be remedied by us free of charge provided the equipment is returned to our Workshop within a period of twelve 12 months from date of delivery freight paid both ways In the case of warranty service to equip...

Page 9: ...erive the velocity time data set 3 Velocity data is then integrated over time to derive the displacement time data set 4 Power is calculated as instantaneous velocity multiplied by instantaneous force that each time point 5 Maximum and minimum as well as average summary variables are being calculated for each data set 6 Additional summary variables such as impulse over defined time periods time to...

Page 10: ...SA 5072 Australia Postal Address PO Box 139 Fullarton 5063 Tel 61 8 8331 9229 Mob 0418 815 400 www fittech com au E info fittech com au Copyright Fitness Technology Adelaide Australia 3rd Feb 2020 Issue 1 00 3rd Feb 2020 For any additional support information send email request to info fittech com au ...

Reviews: