background image

 

VPP500 Vacuum Pickup System Operating Manual 

 

 

© 2020 Fisnar 

- 7 - 

VPP500 Rev 01 

EXTERNAL CONTROLS 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FIG. 1: External Controls - Overview 

 

Item 

Illustration 

Item 

Illustration 

Item 

Illustration 

Power Indicator Light 

Vacuum Control 

ESD Grounding Point 

Vacuum Inlet Port 

Foot Switch Connector 

10 

Exhaust Port 

ESD Input Connector 

Power Input Connector 

11 

Air Inlet Port 

Vacuum Pressure Gauge 

Power On/Off Switch 

 

 

 

 

REAR 

FRONT 

10 

11 

Summary of Contents for VPP500

Page 1: ...VPP500 Vacuum Pickup System Operating Manual info fisnar com www fisnar com...

Page 2: ...Fisnar 2 VPP500 Rev 01 Table of Contents Machine Overview 3 Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine Setup 10 Vacuum Pickup Pen Setup 11 Operation Mode 12...

Page 3: ...component 2 The foot pedal switch is then pressed and kept held down to apply the vacuum through the suction cup 3 This then allows the component to be picked up and safely positioned 4 The foot peda...

Page 4: ...ke or use near an open flame Do not expose the machine directly to sunlight Avoid cleaning the machine with aggressive solvents neutral detergents are preferred Place the vacuum pickup pen in the supp...

Page 5: ...avoid any fire or explosion Assess your surroundings and the location of the nearest fire extinguisher and Emergency Exit Do not smoke or use near an open flame Immediately disconnect power if any spa...

Page 6: ...p Pen part 580046NH ESD Workstation kit part ESD WSK US ESD WSK EU ESD WSK UK available to purchase separately Part 580046NH SPECIFICATIONS Dimensions W x D x H 5 12 x 5 04 x 3 00 130 x 128 x 76 mm We...

Page 7: ...Item Illustration Item Illustration Item Illustration 1 Power Indicator Light 5 Vacuum Control 9 ESD Grounding Point 2 Vacuum Inlet Port 6 Foot Switch Connector 10 Exhaust Port 3 ESD Input Connector...

Page 8: ...e This does not apply if using optional vacuum pickup pen 580046NH 4 Digital Display Screen Shows the amount of vacuum pressure being used to pick up a component by the suction cup The vacuum pressure...

Page 9: ...1911 is connected here 3 On Off Switch Used to switch the machine on or off 4 ESD Grounding Point ESD grounding cable 5601947 is connected here The other end of the cable is to be connected to a suita...

Page 10: ...t on the back of the machine See FIG 4 4 Insert the air connector and ESD grounding plug 4 from the vacuum pickup pen to the ports on the front of the machine See FIG 4 If using optional vacuum pickup...

Page 11: ...stem of the vacuum cup onto the pickup tip See FIG 5 Ensure that the pickup tip does not protrude into the cup area of the vacuum cup as this may result in damaging the component that is to be picked...

Page 12: ...ol knob to increase the vacuum pressure by slowly turning it counterclockwise to a suitable level where there is enough force to securely seal the suction cup to the component See FIG 6 This step is o...

Page 13: ...7 External Machine Actuation Input A dry contact closure 0 Volt between the Input Pin 1 and Common Pin 2 pins will trigger a dispense signal See FIG 7 PLEASE READ Do not apply a voltage between the i...

Page 14: ...1887 10FT 6mm Transparent PU Tubing 10ft 8 5601906 Vacuum Transducer inc fittings 9 5601940 Air in Out Module 10 5601946 ESD Socket Assembly 11 5601944 On Off Switch Assembly 12 5601909 Power Input Co...

Page 15: ...tion 1 QK VTK Vacuum Tip Selection Kit 2 580052 14ga 45 Vacuum Pickup Tip 3 580053 18ga 45 Vacuum Pickup Tip 4 5601942 14ga Vacuum Pickup Tip 5 5601941 18ga Vacuum PickupTip 6 580047 Vacuum Cup 3mm 7...

Page 16: ...of the equipment to the factory during the warranty period of the equipment In no event shall any liability or obligation of Manufacturer arising from this warranty exceed the purchase price of the eq...