EXTERNAL CONTROLS 

 
 
 
 
 
 
 
 
 
 
 

 
 

 
 

FIG. 2: External Controls – Front 

 

1. 

Vacuum Inlet Port 

The air connector on the vacuum pickup pen is connected here. 

2. 

ESD Input 

Connector 

 
The electrical plug on the vacuum pickup pen is connected here. 
 

This does not apply if using optional vacuum pickup pen (#580046). 

 

3. 

Vacuum Control 

 
Adjusts the amount of vacuum pressure being used, for the suction cup 
to safely and securely pick up the component.  
 
Turn  the  knob  counterclockwise  to  increase  the  vacuum  pressure  to 
the desired level. 
 

Vacuum pressure will not be generated until the foot pedal has been 
pressed. 

 

 
 
 
 
 
 
 

 

 

Summary of Contents for VPP50

Page 1: ...VPP50 Vacuum Pickup System Operating Manual info fisnar com www fisnar com...

Page 2: ...Fisnar 2 VPP50 Rev 01 Table of Contents Machine Overview 3 Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine Setup 10 Vacuum Pickup Pen Setup 11 Operation Mode 12...

Page 3: ...or s finger is then positioned over the hole on the finger grip of the vacuum pickup pen and kept held down to apply the vacuum through the suction cup 3 This then allows the component to be picked up...

Page 4: ...smoke or use near an open flame Do not expose the machine directly to sunlight Avoid cleaning the machine with aggressive solvents neutral detergents are preferred Place the vacuum pickup pen in the s...

Page 5: ...the following instructions to avoid any fire or explosion Assess your surroundings and the location of the nearest fire extinguisher and Emergency Exit Do not smoke or use near an open flame Do not e...

Page 6: ...ard Vacuum Pickup Pen part 580046 ESD Workstation kit part ESD WSK US ESD WSK EU ESD WSK UK available to purchase separately Part 580046 SPECIFICATIONS Dimensions W x D x H 3 78 x 5 04 x 3 00 96 x 128...

Page 7: ...0 Fisnar 7 VPP50 Rev 01 EXTERNAL CONTROLS FIG 1 External Controls Overview Item Illustration Item Illustration 1 Vacuum Inlet Port 5 ESD Grounding Point 2 ESD Input Connector 6 Air Inlet Port 3 Vacuum...

Page 8: ...The electrical plug on the vacuum pickup pen is connected here This does not apply if using optional vacuum pickup pen 580046 3 Vacuum Control Adjusts the amount of vacuum pressure being used for the...

Page 9: ...n be fitted into the exhaust outlet port to reduce the emitted noise of the exhausted air 2 ESD Grounding Point ESD grounding cable 5601947 is connected here The other end of the cable is to be connec...

Page 10: ...the ports on the front of the machine See FIG 4 If using optional vacuum pickup pen 580046 only the air connector will need to be attached to the port on the front of the machine 3 Insert the ESD gro...

Page 11: ...stem of the vacuum cup onto the pickup tip See FIG 5 Ensure that the pickup tip does not protrude into the cup area of the vacuum cup as this may result in damaging the component that is to be picked...

Page 12: ...tion cup 3 Use the vacuum control knob to increase the vacuum pressure by slowly turning it counterclockwise to a suitable level where there is enough force to securely seal the suction cup to the com...

Page 13: ...3 5601941 Vacuum Control Valve inc fittings 4 5601887 10FT 6mm Transparent PU Tubing 10ft 5 5601940 Air In Out Module 6 5601946 ESD Socket Assembly 7 5601906 Vacuum Transducer inc fittings 8 561851 A...

Page 14: ...ion 1 QK VTK Vacuum Tip Selection Kit 2 580052 14ga 45 Vacuum Pickup Tip 3 580053 18ga 45 Vacuum Pickup Tip 4 5601942 14ga Vacuum Pickup Tip 5 5601941 18ga Vacuum PickupTip 6 580047 Vacuum Cup 3mm 7 5...

Page 15: ...of the equipment to the factory during the warranty period of the equipment In no event shall any liability or obligation of Manufacturer arising from this warranty exceed the purchase price of the eq...

Reviews: