Cycle Mode 

 
Cycle Mode allows the user to create a  repeating cycle of dispensing. This is programed by setting a  wait time between 
dispensing.  This  mode  is  reliant  on  the  previous  setting  that  was  made  in  Timer  Mode  to  determine  the  length  of 
dispensing during the cycle. 

For Example:

 If  you  would like to dispense for 1 second then  wait for 5 seconds and cycle these  times over again  you 

would  need  to  have  already  set  your  Timer  Mode  for  1  second  (see  previous  page  for  these  instructions).  To  set the  5 
second wait time in your cycle follow the below directions. 
 

1.  Press the 

Mode

 button until the Cycle Mode is selected. 

 

 

 

2.  Press the 

Set

 

button. The first digit on the right side of the display will start blinking. 

 

 

 

3.  Press the 

◄ button 

two times. The third digit from the right should be blinking. 

 

 

 

4.  Press the 

▲ button f

ive times. The display should now show a 5 second wait time. (To adjust the decimal refer to 

page 11) 

 

 

 
5.  Press 

Exit/Mode

 to save as current setting. 

 
 
To use the cycle mode press the 

SHOT

 button on the SL101N to activate the cycle. To deactivate the cycle press the 

EXIT

 button.

Summary of Contents for SL101N

Page 1: ...P N 562179 REV C Dec 2011 1 2011 Fisnar SL101N DIGITAL LIQUID DISPENSER O OP PE ER RA AT TI IN NG G M MA AN NU UA AL L...

Page 2: ...P N 562179 REV C Dec 2011 2 2011 Fisnar This page intentionally left blank...

Page 3: ...Voltage 24VDC Cycle Speed 600 Minute Air Input 70 100psi 5 7 bar Air Output 1 100psi 0 1 7 bar Standards European CE approved unit Barrel Suck Back Feature The SL101N digital liquid dispenser with its...

Page 4: ...ot Switch Plug 3 Insert and twist male quick connect into dispenser 4 Insert power cord female plug into dispenser and insert the male plug into a grounded outlet 5 Fill barrel with barrel tip cap on...

Page 5: ...lay Displays information pertaining to the programming and use of the unit SET Used as an up scroll key and to begin the programming of a mode MEM Used as a down scroll key and to save recall a progra...

Page 6: ...pedal or pressing the SHOT button as soon as either of these are released the dispensing will stop The unit will also count the amount of time you are dispensing during a cycle which may be helpful i...

Page 7: ...e Timer Mode is selected 2 Press the SET button The first digit on the right side of the display will start blinking 3 Press the button twice The third digit from the right should be blinking 4 Press...

Page 8: ...ur Timer Mode for 1 second see previous page for these instructions To set the 5 second wait time in your cycle follow the below directions 1 Press the Mode button until the Cycle Mode is selected 2 P...

Page 9: ...n also save your Cycle Mode settings to program 9 by following the same procedure To save your current settings to memory address 9 follow the below instructions 1 Change to the mode you would like to...

Page 10: ...To load the cycle time that was saved in memory 9 on the previous page follow the below steps 1 Switch to Cycle Mode then press and hold the MEM Memory key for 2 seconds until the unit beeps 2 The di...

Page 11: ...f left sitting for long periods of time Before auto purging your material be sure to read over the material MSDS for any precautions that may need to be taken Also be sure that you have a proper stora...

Page 12: ...defective upon prepaid return of the equipment to the factory during the warranty period of the equipment In no event shall any liability or obligation of Manufacturer arising from this warranty excee...

Reviews: