background image

P/N 562179 

 

 

     REV. C Dec 2011 

© 2011 Fisnar 

Manual Mode 

 

Manual Mode allows the user to dispense for an unlimited amount of time by either pressing down on the supplied foot 
pedal or pushing the 

SHOT

 button on the front of the SL101N unit. The material will continue to dispense for as long as 

the user is pushing down on the foot pedal or pressing the 

SHOT

 button, as soon as either of these are released the 

dispensing will stop.  
 
The unit will also count the amount of time you are dispensing during a cycle which may be helpful in determining a time 
to be used when programming the timer mode. If you need to adjust the decimal point to allow for the timer to show a 

higher or smaller value press the SET button then use the ▲ and ▼ to adj

ust the position. 

 

1. Press the 

MODE

 button to cycle to Manual Mode. 

   

 

 

2. The 

SHOT

 button is located at the circled area below. 

 

 

 

Summary of Contents for SL101N

Page 1: ...P N 562179 REV C Dec 2011 1 2011 Fisnar SL101N DIGITAL LIQUID DISPENSER O OP PE ER RA AT TI IN NG G M MA AN NU UA AL L...

Page 2: ...P N 562179 REV C Dec 2011 2 2011 Fisnar This page intentionally left blank...

Page 3: ...Voltage 24VDC Cycle Speed 600 Minute Air Input 70 100psi 5 7 bar Air Output 1 100psi 0 1 7 bar Standards European CE approved unit Barrel Suck Back Feature The SL101N digital liquid dispenser with its...

Page 4: ...ot Switch Plug 3 Insert and twist male quick connect into dispenser 4 Insert power cord female plug into dispenser and insert the male plug into a grounded outlet 5 Fill barrel with barrel tip cap on...

Page 5: ...lay Displays information pertaining to the programming and use of the unit SET Used as an up scroll key and to begin the programming of a mode MEM Used as a down scroll key and to save recall a progra...

Page 6: ...pedal or pressing the SHOT button as soon as either of these are released the dispensing will stop The unit will also count the amount of time you are dispensing during a cycle which may be helpful i...

Page 7: ...e Timer Mode is selected 2 Press the SET button The first digit on the right side of the display will start blinking 3 Press the button twice The third digit from the right should be blinking 4 Press...

Page 8: ...ur Timer Mode for 1 second see previous page for these instructions To set the 5 second wait time in your cycle follow the below directions 1 Press the Mode button until the Cycle Mode is selected 2 P...

Page 9: ...n also save your Cycle Mode settings to program 9 by following the same procedure To save your current settings to memory address 9 follow the below instructions 1 Change to the mode you would like to...

Page 10: ...To load the cycle time that was saved in memory 9 on the previous page follow the below steps 1 Switch to Cycle Mode then press and hold the MEM Memory key for 2 seconds until the unit beeps 2 The di...

Page 11: ...f left sitting for long periods of time Before auto purging your material be sure to read over the material MSDS for any precautions that may need to be taken Also be sure that you have a proper stora...

Page 12: ...defective upon prepaid return of the equipment to the factory during the warranty period of the equipment In no event shall any liability or obligation of Manufacturer arising from this warranty excee...