background image

ADMINISTRATOR AND SUPERVISOR MANUAL

Dispensing Innovation™

LD

S9

000

®

Programming the 

SmartDispenser

®

Traditional LDS9000

®

 Mode

Summary of Contents for SmartDispenser LDS9000

Page 1: ...ADMINISTRATOR AND SUPERVISOR MANUAL Dispensing Innovation LDS9000 Programming the SmartDispenser Traditional LDS9000 Mode ...

Page 2: ...3 Fishman Corporation USA Toll Free 1 800 433 2115 3 Fishman Corporation USA Toll Free 1 800 433 2115 Fishman Corporation USA Toll Free 1 800 433 2115 ...

Page 3: ...ENSING This setup guide is designed to help Administrators and Supervisors quickly and easily get the SmartDispenser system running and logon to Traditional LDS9000 Mode If you are unsure of any step or have questions consult your SmartDispenser Setup Guide contact your Fishman distributer or call us at one of the numbers below US Canada 800 433 2115 Worldwide 1 508 435 2115 ...

Page 4: ...up your SmartDispenser 7 components 4 0 Startup and Logon the 10 LDS9000 Traditional Mode of SmartDispenser 5 0 Assembly of all SmartDispenser 12 LDS Dispense Guns 6 0 Attach the Genius Barrel 13 Reservoir to LDS Dispense Gun 7 0 Prime the Genius FreeFlow 16 Dispense Tip 8 0 Setup a LDS9000 Traditional 18 Mode Program 9 0 Activate your SmartDispenser 25 Warranty Online ...

Page 5: ...ncorp com 6 1 0 Prepare your workspace for the SmartDispenser 1 1 Be sure your work area has access to electrical power You will not need compressed air The SmartDispenser works without air International 00 1 508 435 2115 www fishmancorp com 5 ...

Page 6: ...6 Fishman Corporation USA Toll Free 1 800 433 2115 2 0 Unpack your SmartDispenser System 2 1 Remove all items from the box 2 2 Use the checklist provided to confirm that all components are present ...

Page 7: ... www fishmancorp com 8 International 00 1 508 435 2115 www fishmancorp com International 00 1 508 435 2115 www fishmancorp com 7 3 Hook up your SmartDispenser components 3 1 Refer to the diagram to connect all components and peripheral devices to the SmartDispenser Q A B R N E J F G P O ...

Page 8: ...D Foot Pedal Connector E Keyboard F Mouse G USB connectors H Ethernet Port I Cisco Wireless Connectivity Device J Video Camera K Power Cord L Universal Power Supply M Power Supply Connector N On Off Button O Power Light P Touch Screen Q Earphone R Earphone Port 8 Fishman Corporation USA Toll Free 1 800 433 2115 ...

Page 9: ...ur SmartDispenser to an Ethernet network using the Ethernet port H found on the back of the unit If you have a wireless network install the supplied wireless connectivity device I in one of the USB connectors G located on the front and back of the unit 3 6 Plug the supplied video camera J into one of the four USB connectors G located on the front and back of the SmartDispenser 3 7 Connect the powe...

Page 10: ...115 4 0 Startup and Logon the LDS9000 Traditional Mode of SmartDispenser 4 1 Press the black startup button N on the front of the SmartDispenser The green power light will illuminate O 4 2 On home screen Tap click on the LDS9000 Traditional mode icon ...

Page 11: ...nternational 00 1 508 435 2115 www fishmancorp com 11 4 3 On SmartDispenser Logon screen select Administrator or Supervisor from drop down menu Tap click password 1234 tap click OK tap click Logon button ...

Page 12: ...S Dispense Guns 5 1 The SmartDispenser dispense guns are available in many configurations The gun connectors are similar for easy hook up to the SmartDispenser SurLok Retaining Ring Cover Genius Tip Cap Genius Barre Reservoir Genius Posilok Piston Piston Hub Lead Screw LDAV MDAV or SDAV Gun ...

Page 13: ... 2115 www fishmancorp com 13 6 0 Attach the Genius Barrel Reservoir to LDS Dispense Gun 6 1 Verify the AUTO Manual button is set to MANUAL Auto Verify the EXTEND Retract button is set to EXTEND Retract EXTEND Retract MANUAL Auto ...

Page 14: ...the barrel reservoir over the piston hub of the dispensing gun 6 4 Holding both barrel reservoir and dispense gun loosely step on the foot pedal until the barrel reservoir ears are raised at least 1 4 6 35 mm above the plate 6 5 Manually twist the barrel reservoir in a clockwise direction until the luer lock connector is finger tight and the ears of the barrel reservoir are flush against the retai...

Page 15: ...ring the ears completely flush to the retaining plate If you set the switch to RETRACT Extend be sure it is set back to EXTEND Retract before proceeding 6 6 Slide the retaining ring cover over the Genius barrel reservoir and align the legs with the open slots of the adapter plate For threaded retaining rings simply engage threads and tighten as you would any beverage bottle 6 7 Rotate the retainin...

Page 16: ... pedal intermittently until the fluid begins to flow towards the end of the Genius FreeFlow tip Goal To stop the fluid when flush with the end of the Genius FreeFlow tip with no air pockets Tip Genius all plastic FreeFlow tips work best There are multiple size tips indicated by color To find the tip that works best increase or decrease gauge size If a stainless steel dispense tip is necessary alwa...

Page 17: ...it appears as pictured Note If the material continues to ooze repeat step 7 4 to 7 5 7 7 On the control panel tap click the RETRACT Extend button to EXTEND Retract 7 8 Tap click MANUAL Auto button to AUTO Manual 7 9 Tap click the arrow next to Barrel Size to drop down menu and select the size of the syringe barrel you are using 7 10 Tap click OK on the pop up message EXTEND Retract RETRACT Extend ...

Page 18: ...art Length Width 1 64 0 396mm 1 32 0 795mm 1 16 1 59mm 3 32 2 38mm 0 1 0 00030 cc 0 00126 cc 0 00500 cc 0 01130 cc 1 0 00310 cc 0 01261 cc 0 05030 cc 0 11300 cc 2 0 00630 cc 0 02522 cc 0 10050 cc 0 22600 cc 3 0 00940 cc 0 03783 cc 0 15080 cc 0 33899 cc 4 0 01250 cc 0 05044 cc 0 20110 cc 0 45199 cc 5 0 01570 cc 0 06304 cc 0 25140 cc 0 56499 cc 6 0 01880 cc 0 07565 cc 0 30160 cc 0 67799 cc 7 0 02190...

Page 19: ...69 0 11 2 79 l 0 00941 0 13 3 30 l 0 01448 0 15 3 81 l 0 02096 0 17 4 31 l 0 02950 0 19 4 83 l 0 04573 0 22 5 59 l 0 05913 0 24 6 09 l 0 07527 0 26 6 60 l 0 11583 0 30 7 62 l 0 18394 0 35 8 89 l 0 27457 0 40 10 16 l 0 39094 0 45 11 43 l 0 53627 0 50 12 70 l 1 80990 0 75 19 05 l 8 6 Select the dot size closest to your target dispense size on the 9B Dot Chart to the right Review information on pages...

Page 20: ...nput boxes 1 Tap click the input box left right arrows will appear Tap click either arrow to increase or decrease the number 2 Tap click a second time to get the arrows to separate revealing a slide bar Tap click either arrow to increase decrease the number or tap click and hold grey slider rectangle sliding in either direction for rapid number change 8D Dot Anatomy 8C Anatomy Length Width D Volum...

Page 21: ...ter button the keypad will automatically move to the next dispense parameter Tip Use the four arrow keys to move up and down from one dispense parameter to another Also use four left right arrow keys to increase and decrease program parameter number Tap click anywhere outside the key pad to close International 00 1 508 435 2115 www fishmancorp com 21 ...

Page 22: ...using one of the input methods explained on pages 19 and 20 8 8 Input the dispense rate in Speed cc per sec box using one of the input methods explained on pages 19 and 20 8 9 Set Back off steps to 10 using one of the input methods explained on pages 19 and 20 8 10 Tap click MANUAL Auto button so AUTO Manual is selected MANUAL Auto AUTO Manual ...

Page 23: ...14 Tap click the AUTO Manual button to MANUAL Auto and then tap click the EXTEND Retract button to RETRACT Extend 8 15 Press the foot pedal as many times as needed to stop the fluid flow If you go too far and suck fluid into the tip tap click RETRACT Extend to EXTEND Retract and repeat until fluid is settled at the tip 8 16 Return to procedural step 8 9 increasing and decreasing Back off steps unt...

Page 24: ... as needed to bring the fluid flush with the tip 8 19 Return to procedural step 8 9 increasing or decreasing back off steps until your dispense tip is flush at end of dispense If flush proceed to 8 20 8 20 Tap click Save Program to save 8 21 Tap click Yes to pop up message 8 22 Tap click OK to pop up message YOU ARE NOW READY TO DISPENSE Save Program EXTEND Retract RETRACT Extend AUTO Manual MANUA...

Page 25: ...an SmartDispenser Genius AirFree PosiLok FreeFlow SafeLok SurLok DripFree LDS9000 and ProcessControl2 are all trademarks of Fishman Corporation 2017 Fishman Corporation Windows is a registered trademark of Microsoft Corporation in the United States and other countries 9 0 Activate your SmartDispenser Warranty Online 9 1 Go to www fishmancorp com warranty and fill out the form to activate your two ...

Page 26: ...33 2115 Fishman Corporation USA Toll Free 1 800 433 2115 Fishman Corporation 192 South Street Hopkinton MA 01748 United States www fishmancorp com US Canada 800 433 2115 United Kingdom 1905 456008 Europe 441905 456008 Worldwide 1 508 435 2115 ...