Switch Response Alerts
1 States (ref):
2 Transition Alert
3 Transition Dwell Alert
4 Transition Dwell
5 Configure:
6 Enable 'In Transition'
7 Enable 'Transition Dwell'
6 Transition Dwell Threshold
Online
1 Overview
2 Configure
3 Service Tools
Configure
1
Guided Setup
2
Manual Setup
3 Alert Setup (see below)
4 Calibration (see below)
Manual Setup
1 Wireless
2 Device
3 Limit Switch Configuration
4 Mapping
5 Fault Behavior
6 Local User Interface
7 Power Module
8 Event Configuration
Identification
1 Tag
2 Long Tag
3 Date
4 Description
5 Message
6 Polling Address
Wireless
1 Network ID
2 Join Device to Network
3 Broadcast Information
Power Module
1 Power Module Type
2 Voltage
3 Power Module Date
4 Battery Life
5 Reset Module Data
Cycle Counter
1 States (ref):
2 Cycle Counter Alert
3 Accumulated Count
4 Reset Accumulated Count
5 Configure:
6 Enable Cycle Count Alert
7 Cycle Trip Point
2
2‐2‐1
2‐2
2‐2‐2
2‐2‐2-1
2‐2‐3
Guided Setup
1 Device Setup
2 Configure Alerts
3 Join Device to Network
4 Configure Publishing
2‐1
Alert Setup
1 Cycle Counter
2 Switch State Alerts
3 Switch Response Alerts
4 Controller Alerts
2‐3
Calibration
1 Calibration Date
2 Sensor Calibration
3 Output Assignment
Broadcast Information
1 Tailor Burst Configuration
2 Set all Burst Messages to Default
3 Hardware Triggering
4 Message 0
5 Message 1
6 Message 2
Mapping
1 Set to Defaults
2 Primary
3 2nd
4 3rd
5 4th
6 Warning Information
Local User Interface
1 Calibration Locked Out
2 Override Locked Out
3 Mode Change Locked Out
4 LUI language
Limit Switch Configuration
1 Switch State
2 Opened/High Trip Point
3 Closed/Low Trip Point
4 Deadband
5 Edit Parameters
2‐2‐4
2‐2‐7
2‐3-2
2‐3-1
Device
1 Identification
2 Structure
3 Discrete Variable Properties
Structure
1 Snap Acting Control
2 Latching Mode
3 Application Mode
4 Configure Structure
5 Operational Options
6 Tracking Debounce
6 Count
2‐2‐2-2
Fault Behavior
1 Active Fault Conditions
2 Enable Fault Conditions
3 Fault Behavior Details
4 Mode
2‐2‐5
2‐2‐6
2
Configure
1 Guided Setup
2 Manual Setup
3
Alert Setup
4
Calibration
Switch State Alerts
1 States (ref):
2 Switch Latched
3 Opened/High Limit Tripped
4 Closed/Low Limit Tripped
5 Configure:
6 Enable 'Latched' Alert
7 Enable 'Opened/High' Alert
8 Enable 'Closed/Low' Alert
Controller Alerts
1 Mode Alerts
2 Tracking Alerts
3 Close Time Alerts
4 Open Time Alerts
2‐4
2‐3-3
2‐3-4
1
1
1
1
1
1
1
2
4
4
3
3
3
1
1
5
Discrete Variable Properties
1 Switch State Properties
2 Set Point Properties
2‐2‐2-4
2‐2‐1-3
6
7
참
:
1
켜짐
/
짐
제어만
해
당
.
2
작동
모드
래
칭
인
우
항
목
라벨은
(
스위
치
상
태
아닌
)
래
칭
스위
치
입니다
(
모니
터
링
또는
스
작동
모드에만
해
당
).
3
스
작동
모드에서는
지
원되
지
않음
.
4
모니
터
링
옵션에서는
OVERRIDE LOCKED OUT(
오버라이드
잠
}) MODE CHANGED LOCKED OUT(
모드
변
잠
})
보이
지
않습니다
.
5
활
성일
때에는
'*`
정되
지
않음
'
보
*`
정
일자를
대
체합
니다
.
6
모니
터
만
해
당
.
7
외부
전력
옵션이
설
치
되어
있으면
전력
모듈
메
a
타
지
않습니다
.