![Fisher FS2MIF-141AE2 Service Manual Download Page 47](http://html.mh-extra.com/html/fisher/fs2mif-141ae2/fs2mif-141ae2_service-manual_2294423047.webp)
9.3.3.8 Temperature protection of compressor discharge (ODU P4)
Temperature
protection
of
compressor
discharge
Check
whether
the
compressor
discharge
temp.
is
more
than
115°C
?
Check whether the
connection is right between
compressor discharge temp.
sensor and PCB according
to wiring diagrams?
Measure the resistance value
of
compressor discharge
temp. sensor.
If the value is
not normal
is
normal refer
to
the
Appendix
2?
No
Yes
Yes
No
Correct the wiring connection
Stop
leaking
and
add
refrigerant
Replace the compressor discharge temp. sensor
No
Yes
Replace high pressure valve assy
Yes
No
Replace outdoor main PCB
No
Check
whether
the
refrigerant
is
leak
Summary of Contents for FS2MIF-141AE2
Page 8: ...5 Wiring diagram FS2MIF 141AE2 FS2MIF 181AE2 FS3MIF 211AE2 FS3MIF 271AE2 8 ...
Page 9: ...FS4MIF 281AE2 FS4MIF 361AE2 9 ...
Page 10: ...FS5MIF 421AE0 10 ...
Page 33: ...9 3 1 2 Indoor outdoor units communication error ...
Page 41: ...9 3 3 2 Communication malfunction between IPM board and outdoor main board ODU E3 ...
Page 44: ...9 3 3 5 High pressure protection ODU P1 For FS4MIF 281AE2 FS4MIF 361AE2 FS5MIF 421AE0 ...
Page 46: ...9 3 3 7 Current protection of compressor ODU P3 ...