Fisher Labs M-Scope Operation Manual Download Page 11

14

sensitivity Menu

The sensitivity setting determines the unit’s ability to detect metal objects. The higher the sensitivity, 
the more responsive it will be to relatively small metal concentrations. To adjust the sensitivity, press 
the sensitivity key (numeral 2). Use the up/down arrows to adjust the sensitivity setting to any number 
from 1 to 99. Sensitivity settings should be selected and adjusted based on your facilities particular 
security needs and operating environment.  The M-Scope will retain your sensitivity settings in memory 
when you turn the power off.

Zone settings

It is possible to adjust the individual zone sensitivities to fine tune the performance of the M-Scope. 
Once in the sensitivity menu, press any key other than the Up, Down or 0 button. This will display the 
Zone select screen. The three bar graphs and numerical reading represent the settings for the TOP (top 
bar graph), MIDDLE (middle bar graph), and Bottom (bottom bar graph) zones. These settings range 
from 0.00 (which corresponds to a zone being completely ignored) to a value of 2.00 (which corresponds 
to a zone having twice the sensitivity as set by the Sensitivity Menu). A value of 1.00 corresponds to 
a zone having an equal setting as the sensitivity menu. Pressing numerals adjusts the settings for the 
zones. Pressing numeral 1, decreases the sensitivity for the top zone. Pressing numeral 2, resets the top 
zone to a value of 1.00. Pressing numeral 3, increases the sensitivity to only the top zone. In similar 
fashion, buttons 4,5 and 6 adjust the zone settings for the middle zone. Buttons 7,8 and 9 adjust the 
settings for the bottom zone. Pressing the Up, Down or 0 numeral, returns to the Sensitivity Menu. 

contrast Menu 

To adjust the LCD display contract press the contract key (numeral 3) when the M-Scope is in normal 
operating mode. Use the up/down arrows to adjust the contract. Contrast settings are automatically 
saved into memory, as well are the user adjusted settings. Press numeral 0 (of wait ten seconds) to exit 
the contrast menu.

 

aDVanceD Functions

You may exit any of these menu modes by pressing the exit key [numeral 0], or by waiting for the ten 
second keyboard timeout, after which the M-Scope will automatically revert to normal operating mode. 
Hold the up/down arrow keys for more than one second for rapid increment or decrement.

Volume Menu

The volume and beep rate are adjustable. To adjust the volume, press the volume key (numeral 1) when 
the M-Scope is in normal operating mode. The unit will start beeping on its own. Use the up/down 
arrow keys to adjust the volume.

 

• To adjust the beep rate, press any button from numeral 1 to 6 while in the volume menu. Below is a 
chart of the beep rate:

Numeral 1 key

Steady tone

All bar graph lights ON

Numeral 2 key

1 Beep/Second

Red LED 7 flashes

Numeral 3 key

2 Beeps/Second

Yellow LED 6 flashes

Numeral 4 key

4 Beeps/Second

Yellow LED 5 flashes

Numeral 5 key

8 Beeps/Second

Green LED 4 flashes

Numeral 6 key

16 Beeps/Second

Green LED 3 flashes

Press numeral 0 [or wait ten seconds]to exit the volume menu. 
The M-Scope will retain your settings in memory when you turn the power off.

 

getting starteD

Digit     exPanDeD abbreViation   

abbreViation

Shut down, [On/Off], Exit   

On/ Off

Volume menu   

 

 

VOL

Sensitivity menu 

 

 

SENS

Contrast menu   

 

 

CON

Counter menu   

 

 

CNT

Rate Alarm menu 

 

 

RATE

Factory Presets   

 

 

FPSET

User Presets 1   

 

 

PRO1

User Presets 2   

 

 

PRO2

User Presets 3   

 

 

PRO3

All  of  the  M-Scope’s  commands  are  entered  through  the 
twelve-button  keypad  on  the  control  unit.  The  two  up/
down  arrows  are  essentially  single  function  buttons. 
The other ten buttons labeled 0 through 9 are all multi-
function  buttons.  Multi-function  buttons  are  annotated 
with corresponding abbreviations. The following is a list of 
the complete expressions for those abbreviations. 

basic start uP oPeration

KeYpaD

COntROL paneL 

(bottom view)

Most often, the operator will simply turn the unit on, and use the settings already stored in memory. For first time use, the unit will 
be set at the Factory Preset setting corresponding to numeral 6/high sensitivity level (for more information - see “Presets” pg.16).

note that these settings may not be appropriate for an operators unique environment and specific security requirements. a thorough 

understanding of the M-scopes operation, and most notably, sensitivity settings, is required for effective, accurate metal detection. 

Turn  the  unit  on  by  momentarily  pushing  the  on/off    [numeral  0]  button  on  the 
control panel keypad. The unit will power up and begin a self diagnostic check.  

The LCD will display the Title Screen and the battery voltage during the self-check. 
The unit will check its seven LED lights on the LED bar graph one at a time, starting 
with the first (lowest) green one, through the yellow ones all the way up to the last 
(highest) red one, then back down to the first green one again. After this check is 
completed, the bar graph display will enter its normal mode, continuously indicating 
the  strength  of  the  received  signal  it  is  measuring.  Some  of  this  signal  may  be  a 
representation of various types of electromagnetic noise, and interference.

During the self check, the multi-colored, triple zone, alarm indicator LEDs 
as well as the two multi-colored ready indicator LEDs

,

 

will glow red momentarily.  

Once the self check ends satisfactorily, they will all change to green.

When the M-scope passes its self check successfully, the unit becomes ready to detect targets.

 

The user selections will be described elsewhere in this document under the Advanced Functions heading.

11

step

1

step

2

the M-scope is Multi language capable:

To change languages: From a fresh start (the Mscope turned off)
1. Press the on button (0) and then rapidly press the down-arrow button and then the up-arrow button.
(This sequence will bring the unit into the first screen of the diagnostics mode.) 

Pressing the 0 button again will bring the unit into the main screen of the diagnostics mode. While in this screen:
Pressing the number 1 button will change the menu into English / Pressing the number 2 button will change the menu into German.

Pressing the number 3 button will change the menu into French / Pressing the number 4 button will change the menu into Spanish.

After selecting the desired language pressing the 0 button will change the unit into the normal operating menus.
The M-scope is the normal operating mode at this time.
When the Mscope is shut down the language and other selected options are saved to memory.

Huvudkontor Order & Lager: Malux Sweden AB, Box 221, 891 25 Örnsköldsvik. Växel 0660-29 29 00, fax 0660-850 85.

Försäljningskontor: Stockholm, Göteborg, Stenungsund, Kalmar. För adresser: www.malux.se.

Huvudkontor Order & Lager: Malux Sweden AB, Box 221, 891 25 Örnsköldsvik. Växel 0660-29 29 00, fax 0660-850 85.

Försäljningskontor: Stockholm, Göteborg, Stenungsund, Kalmar. För adresser: www.malux.se.

Summary of Contents for M-Scope

Page 1: ...ldsvik V xel 0660 29 29 00 fax 0660 850 85 F rs ljningskontor Stockholm G teborg Stenungsund Kalmar F r adresser www malux se Huvudkontor Order Lager Malux Sweden AB Box 221 891 25 rnsk ldsvik V xel...

Page 2: ...ates split cognition freeing operator to monitor surroundings 2 Some objects may not be detected because of their composition size and location on the subject If an undetected object passes through th...

Page 3: ...sher s expertise innovation and reputation for quality metal detection solutions to the critical and demanding security market Huvudkontor Order Lager Malux Sweden AB Box 221 891 25 rnsk ldsvik V xel...

Page 4: ...dity 95 non condensing BATTERY AC POWER 2 rechargeable batteries 40 hours of battery life on a single charge AC power options include 110V 60Hz or 220V 50Hz Warranty 24 months parts and labor NOTE Thi...

Page 5: ...emember the following tips for caring and maintaining your M Scope Check the spring contact pins and boards for dirt and debris When cleaning your M Scope use a damp cloth only Do not submerge the bas...

Page 6: ...Light OFF Ready Light OFF Numeral 4 key Bar graph LED 4 on GREEN Top Zone Light GREEN Middle Zone Light GREEN Bottom Zone Light GREEN Status Light OFF Ready Light OFF Numeral 5 key Bar graph LED 5 on...

Page 7: ...e alphanumeric characters between the pairs of ovals represent the magnitudes of the three zones most recent target measurements These values are expressed in hexadecimal engineering units and they va...

Page 8: ...ope to use any of these four Preset groups simply press the corresponding numeral key when the M Scope is in normal operating mode For example pressing the numeral 8 key will set the M Scope to the co...

Page 9: ...wait ten seconds to exit the Access menus Access Menus Password Protection Continued Default Codes MASTER 1 01 USER 2 1 USER 3 2 USER 4 3 Lay out the transport straps on the spot where you will stack...

Page 10: ...violation While in the Rate Alarm Menu a user can choose to set the M Scope to an Entrance Only Active mode In this mode the M Scope alarms and counts people that enter the unit through the entrance...

Page 11: ...RATE 6 Factory Presets FPSET 7 User Presets 1 PRO1 8 User Presets 2 PRO2 9 User Presets 3 PRO3 All of the M Scope s commands are entered through the twelve button keypad on the control unit The two up...

Page 12: ...a time No more than two can glow yellow alternating red and green at a time Any combination of green zone indicators is possible After finding target s the audio alert will continue to beep and the al...

Reviews: