DO NOT DRAG the cooker. Lift
the feet clear of the floor.

Fig. 5c Incorrectly raising the cooker

Ventilation Requirements (GB & IE only)

The appliance should be installed in a room or space with an air supply in accordance with BS 5440-2:2000.
For rooms with a volume of less than 5 m3 : permanent ventilation of 100 mm3 free area will be required.
For rooms with a volume of between 5 m3 and 10 m3 : permanent ventilation of 50 cm3 free area will be required unless
the room has a door which opens directly to the outside air, in which case no permanent ventilation is required.
For rooms with a volume greater than 10 m3 : no permanent ventilation is required.

Regardless of room size, all rooms containing the appliance must have direct access to the outside
air via an openable window or equivalent.

Where there are other fuel burning appliances in the same room, BS 5440-2:2000 should be consulted to determine the
correct amount of free area ventilation requirements.

https://producthelp.fisherpaykel.com/eu/Cook/Freestanding_Cookers/Dual_Fuel/OR120DDWGFX2/User_Guide_OR120DDW…

Updated: Fri, 15 Jan 2021 11:10:49 GMT

Powered by

6

Summary of Contents for OR120DDWGFX2

Page 1: ...Fig 1 Assembling the Backguard Installing the backguard is MANDATORY https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated Fri 15 Jan 2021...

Page 2: ...exceeds the height of the hob surface Fig 3a or 3b The appliance must be housed in heat resistant units The walls of the units must be capable of resisting temperatures of 75 C above room temperature...

Page 3: ...and to ensure adequate ventilation the cooker chassis MUST NOT sit directly on the floor a plinth or other support surface The cooker is already fitted with six levelling feet Level the cooker by scre...

Page 4: ...Fig 4a Fig 4b Fig 4c Fig 4d https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated Fri 15 Jan 2021 11 10 49 GMT Powered by 4...

Page 5: ...adjustable feet Fig 5a Correctly raising the cooker Do not lift the cooker by the door handles Fig 5b Incorrectly moving the cooker https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dua...

Page 6: ...the room has a door which opens directly to the outside air in which case no permanent ventilation is required For rooms with a volume greater than 10 m3 no permanent ventilation is required Regardles...

Page 7: ...orrectly could invalidate any manufacturer s warranty and lead to prosecution under the above quoted regulation Gas Connection The installation of the cooker to Natural Gas or LP Gas must be carried o...

Page 8: ...be crushed or trapped or be in contact with sharp or abrasive edges It should also not be subjected to corrosion by acidic cleansing agents To Connect the Gas Supply 1 Fit the 1 2 BSP female connector...

Page 9: ...D and into the cable protector C The supply cable must be of a suitable size for the current requirements of the appliance see Feeder Cable section following Connect the phase and earth cables to term...

Page 10: ...eeder Cable Section TYPE H05RR F 230V 3 x 2 5 mm2 Connection with wall box connection https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated...

Page 11: ...Fig 7c https producthelp fisherpaykel com eu Cook Freestanding_Cookers Dual_Fuel OR120DDWGFX2 User_Guide_OR120DDW Updated Fri 15 Jan 2021 11 10 49 GMT Powered by 11...

Reviews: