599328A GC912/913 Gas cooktop
14
These repairs
require gas
qualifications
.
NO
YES
YES
NO
NO
YES
*
Sparking continuously
Is a burner in
use?
Does the burner
light and
continue
sparking?
Refer to Burner not lighting flowchart
Check for:
shorted ignition switches in the loom
incorrect polarity at the power outlet.
Check the:
electrode/burners are clean and dry
low flame setting is correctly set
**
electrode leads are firmly connected to their correct location at the
ignition box and are not damaged
earth to the cooktop and earthing connections in the cooktop are ok.
NOTES
*
Indicates the flame isn’t being sensed.
**
The correct
electrode positions at the ignition box -
Is the flame
behaving
normally?
Check the:
burner components are assembled correctly, are clean and dry
and not distorted
gas jet is the correct size for the gas type and is not blocked
low flame setting is correctly set
cooktop doesn’t require high altitude jets.
Replace the ignition box
Check the gas pressure
Terminal Burner
S1 Front
left
S2 Front
right
S3 Middle
S4 Rear
left
S5 Rear
right