8.13 Removing the Flow Meter
8.12 Removing the Diverter Valve
FC4 &6 models only
•
Remove the product from the joinery.
•
Remove the base panel from the machine, and
disconnect the flood switch assembly to remove
the base panel completely.
•
Remove the wiring harness to the diverter valve.
•
Remove the clamp securing the diverter valve to
the sump.
•
Pull the valve off the sump spigot.
•
When reassembling ensure the o-ring is fitted
correctly to ensure sealing.
•
Use a standard hose clamp to secure diverter
valve to the sump, reconnect the wiring.
•
Remove the product from the joinery.
•
Remove the side panel, refer section 8.3
•
Remove the harness to the flow meter.
•
Remove the hoses to the flow meter.
•
Remove the vent cap from the inside of the
wash tub. The assembly will now remove from
the chassis.
8 SERVICING THE COMPONENTS
D
D
8.11 Removing the Turbidity/Temperature Sensor
•
Remove the product from the joinery.
•
Remove the base panel from the machine, and
disconnect the flood switch assembly.
•
Remove the wiring harness to the turbidity
sensor.
•
Remove the 2 screws securing the turbidity
sensor to the sump.
•
Pull the sensor out to release from the sump.
•
Reassemble in reverse order.