CUSTOM PANEL DIMENSIONS

CABINETRY DIMENSIONS

STANDARD 

INSTALL

ASSISTED OPENING 

INSTALL**

MM

MM

Minimum panel height*

452

498

Minimum panel width

596

596

Panel depth

16 - 20

16 - 20

Minimum clearance between base of door panel and 
cabinetry

2

2

Minimum clearance between top of door panel and 
countertop

2

2

*Core panel dimension. Panel can be extended or lowered to suit installation
**for more information on panel placement refer to fisherpaykel.com

ISO

PROFILE

Material specifications

 

z

Maximum weight of panel must not exceed 9kg (including handle)

 

z

The panel should be adequately sealed to withstand moisture (50°C @ 
80% RH). The back and sides of the panel should be completely sealed 
with a waterproof vapour barrier, such as polyurethane, to prevent damage.

 

z

The back of the panel should be completely flush so that the seal between 
the panel and the rubber trim is maintained.

 

z

Installation outside these specifications may result in condensation on 
cabinetry surfaces.

A

A

D

e

C

B

C

Standard installation illustrated

Summary of Contents for DISHDRAWER DD60STX6HI1

Page 1: ...INSTALLATION GUIDE INTEGRATED DD60STX6I1 DD60STX6HI1 SINGLE DISHDRAWER DISHWASHER NZ AU BI...

Page 2: ......

Page 3: ...be plugged into an appropriate outlet that is installed and earthed in accordance with all local codes and ordinances Do not modify the power supply plug provided with the appliance if it will not fit...

Page 4: ...Regulations z The DishDrawer Dishwasher MUST be installed to allow for future removal from the enclosure if service is required z The switched power outlet must be outside the dishwasher cavity so tha...

Page 5: ...asher 1 Drain hose support 1 Flat blade screwdriver Level Top mounting bracket kit 1 38mm bottom fixing screws and washers 2 Drain hose joiner 1 Powered driver Pliers Box cutter Router Pencil Multi to...

Page 6: ...height 454 B Overall width 599 C Overall depth 571 D Depth of chassis 553 E Front panel depth 16 20 F Max drawer extension 527 based on front panel thickness of 18mm refer to Custom panel dimension f...

Page 7: ...an 18mm high spacer and two 55mm high spacer blocks including 18mm door panels on adjacent cabinetry when venting through the same or adjacent cabinet Refer to External venting preparation for more in...

Page 8: ...8 CABINETRY CLEARANCES MM A Minimum clearance to adjacent cabinetry 2 B Minimum clearance to corner cabinetry 13 B A PLAN CLEARANCES...

Page 9: ...n panel placement refer to fisherpaykel com ISO PROFILE Material specifications z Maximum weight of panel must not exceed 9kg including handle z The panel should be adequately sealed to withstand mois...

Page 10: ...ices can be installed to either the left hand or right hand side of the product in an adjacent cabinet Refer to Cabinetry preparation for service access requirements z If the drain hoses supplied are...

Page 11: ...service hole 10 C Minimum diameter of service hole 57 D If venting through the adjacent cabinetry the rear edge of the service hole should be enlarged by cutting out the bottom corner A B C D z Servi...

Page 12: ...ice hole must be also be created through the shelf and the base of the cavity to route the venting hose through z Frameless cabinetry A 100mm x 200mm cutout must be created at the front of the cabinet...

Page 13: ...e product to either the left or right depending on your venting location Push the vent hose onto the elbow firmly to secure We recommend fitting the trim bracket when installing your DishDrawer Dishwa...

Page 14: ...o secure Push the duct onto the cabinetry and secure using the four provided screws Framed cabinetry Route the venting hose to the cutout and push onto the duct firmly to secure Place duct into cutout...

Page 15: ...s oriented correctly and is not in contact with the bracket before securing On the back of the panel mark the centre and align the base of the bracket with the base of the panel Re insert both side pi...

Page 16: ...sulation is replaced correctly 3 1 2 4 Open the drawer and press both locking tabs back to release Lift the drawer off the runners and set aside on a protected surface Push runners back in Take care n...

Page 17: ...se is routed straight to the joiner removing excess drain hose if necessary Do not shorted the inlet hose Unplug or drill out the waste tee before securing joiner to sink trap or waste tee Plug produc...

Page 18: ...highloop Ensure inlet hose has supplied rubber washer fitted and that it s tightened If connecting the drain hose to the sink trap ensure the highloop is a minimum 150mm higher than the drain hose jo...

Page 19: ...ed z Ensure power is connected and is switched on z AUTO POWER ON may need to be activated Refer to your User guide for details Drawer doesn t close properly z Ensure nothing is obstructing the drawer...

Page 20: ...e product specifications in this guide apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at an...

Reviews: