![Fisher & Paykel Dishdrawer DD60DI Installation Manual Download Page 31](http://html1.mh-extra.com/html/fisher-and-paykel/dishdrawer-dd60di/dishdrawer-dd60di_installation-manual_2295518031.webp)
7
5
CUSTOM DRAWER PANEL CALCULATIONS
The following calculations assume the top of the upper panel is
aligned with the top of the adjacent cabinetry.
WIDTH OF THE PANEL
Measure
A
(the width between adjacent door/drawer fronts)
and write it in the first box below, then complete the equation.
HEIGHT OF THE PANEL
min. 2mm
Ventilation Gap
(min. 2mm)
with External Venting
Kit installed
Ventilation Gap (min. 2mm)
with External Venting Kit installed
min. 2mm
min. 2mm
min. 2mm
WIDTH OF PANEL
HEIGHT OF
PANEL
PANEL
B
A
A
B
Clearance to adjacent
cabinet front
(min. 2mm)
(min. 2mm)
(596 - 615mm)
Ventilation Gap
WIDTH OF PANEL
HEIGHT OF PANEL
Note: when the top of the dishwasher
has to be lower than the adjacent
cabinetry, the top of the panel can
extend above the chassis where required,
however a min. 2mm gap to
the benchtop must be maintained.
DD*SLI9 models only:
This model is installed conventionally without an External Venting Kit.
Therefore, the Ventilation Gap below the product in all calculations is min. 8mm.
-
2x
=
=
-
FRONT PANEL MATERIAL SPECIFICATIONS
O
16 - 20mm panel thickness
O
Adequately sealed to withstand moisture (50
O
C @ 80% RH)
Because of it being a hot and wet environment generally, the back and sides of the
panel should be completely sealed with a waterproof vapour barrier (ie polyurethane)
to prevent damage to the panel.
O
The back of the panel (including any integrated handle) should be completely flush
so that the seal between the panel and the rubber trim is maintained.
O
Installation outside these specs may result in condensation on cabinetry surfaces.
O
Maximum weight of panel: 9kg