Location Requirements
Bathroom or Bedroom Installation
The Dryer MUST be vented to the outdoors. See EXHAUST information.
Dimensions
Exhaust Outlet Location
Mobile or Manufactured Home Installation
Installation must comply with the current CAN/CSA Z240 MH series Mobile Home Installation
Codes or the Manufactured Home Construction & Safety Standard, title 24, part 32-80 or, when
such standard is not applicable, with American National Standard for Mobile Home, AINSI/NFPA
NO. 501B.
The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile
home structure. (See EXHAUST information).
The vent MUST NOT be terminated beneath a mobile or manufactured home.
The vent duct material MUST BE METAL.
The vent MUST NOT be connected to any other duct, vent, or chimney.
Do not use sheet metal screws or other fastening devices which extend into the interior of the
exhaust vent.
In addition to the above, for gas dryers:
Kit 14-D346-33 MUST be used to attach the dryer securely to the structure.
Provide an opening with a free area of at least 161cm sq. (25 sq. in.) for introduction of outside air
into the dryer room.
Exhaust outlet
298mm (11 /”)
114mm (4 /”)