![Fisher & Paykel DD247 Service Manual Download Page 64](http://html1.mh-extra.com/html/fisher-and-paykel/dd247/dd247_service-manual_2295346064.webp)
64
9.15 Wiring Cover
1.
Remove the drawer front (refer section 9.2)
2.
With the tub in the open position, carefully release the
four wiring cover clips, two on each side, from under
the front lower section of the tub. Take care not to
damage them.
3.
Release the four clips on the underside of the tub that
attach the wiring cover to the motor assembly outer
lock nut.
4.
Pull the tub fully open and lift it up at the front (this
makes it easier to remove the wiring cover from the
rear of the tub.
5.
The wiring cover may now be carefully moved forward
and downward to release it from the rear of the tub.
6.
To reassemble, first ensure that the wiring harness,
drain hoses and fill hose are located in their correct
positions.
7.
Then refit in reverse manner.
Note:
It may be easier to remove the tub and rotate it
anticlockwise to remove the wire cover (optional) refer
section 9.6.
Clips
Clips
9.16 Tub Disconnection
1.
Remove the drawer front (refer 9.2)
2.
Remove the wiring cover (refer 9.15)
3.
Disconnect the fill hose from the dispenser
( water may drip) refer section 9.9.
4.
Disconnect the chassis harness plug from the
controller.
5.
Remove the wiring cover and the element connector
cover.
6.
Disconnect the element harness plug and earth wire
from the element plate.
7.
Unclip the drain hose cuff from the motor assembly,
taking care not to misplace the non-return flap valve.
8.
Unclip the drain hose, fill hose and the wiring loom
from the under side of the tub.
9.
Remove the tub.
10.
Refit in reverse manner.
NOTE:
When replacing a fill hose, drain hose or wiring
harness, transfer the link support clip markings from the
old parts to the new.
Fill Hose
Drain Hose
Element Cover
Earth Wire
D
D
D
D
D
D
D