Fisher & Paykel DCS WOSU30 Installation Instructions Manual Download Page 3

1

1

4

4

2

3

1

A

4 UNPACK THE OVEN AND REMOVE THE DOOR(S)

B

Double models featured for illustration purposes only

Junction box location 

for: 

undercounter 

installation

Junction box 

location for: 

wall installation

WOU130,WOSU30

Max. current draw:    19.4 A

Max. load:   

4.6 kW

WOUD230,WODU30

Max. current draw:    38.3 A

Max. load:   

9.2 kW

ELECTRICAL CONNECTION TO JUNCTION BOX

5

1

  Disconnect the power supply.

2

  Remove the junction box cover.

3

  Connect the oven cable to the junction box 

through the U.L.-listed conduit connector.

4

  Connect the two black wires together with 

twist-on connectors.

5

  Connect the two red wires together with 

twist-on connectors.  

6

  Connect electrical connection according to 

local codes and ordinances.

If local codes permit connecting the cabinet-
grounding conductor to the neutral white wire 
in the junction box:

7a

  Connect the factory-taped green and white oven 

cable wires to the neutral (white) wire in the 
junction box.

8a

  Replace the junction box cover.

OR

     If local codes DO NOT PERMIT 

connecting the cabinet-grounding 
conductor to the neutral (white) wire in 
junction box:

7b

  Separate the factory-taped green and white 

oven cable wires.

8b

  Connect the white oven cable wire to the 

neutral (white) wire in junction box.

9b

  Connect the green grounding oven cable 

wire to a grounded wire in the junction box.

10b

 Replace the junction box cover.

OR

     If connecting to a four-wire electrical 

system:

7c

  Separate the green and white oven cable wires.

8c

  Connect the white oven cable wire to the 

neutral (white) wire in junction box.

9c

  Connect the green grounding oven cable wire 

to the (green) grounding wire in the junction 
box. 

 

Do not connect the green grounding wire to 
the neutral (white) wire in junction box.

10c

 Replace the junction box cover.

Nameplate

cable from 

power supply

black 

wires

UL - listed 

conduit connector

box

red wires

white and green 

grounding oven 

wires - factory 

taped

UL - listed conduit 

connector

box

cable from 

power supply

white 

wires

red wires

green grounding 

oven wires 

- factory taped

black 

wires

(2,1)  -1- 599990A DCSWOU130&WOUD230install A2 USCA.indd 12/2/10 11:00:52 AM

(2,1)  -1- 599990A DCSWOU130&WOUD230install A2 USCA.indd 12/2/10 11:00:52 AM

Summary of Contents for DCS WOSU30

Page 1: ...ht The countertop and oven cavity are square and level and are the required dimensions The height from the floor suits the user The oven door can open fully without obstruction Electrical requirements Connect oven with copper wire only Do not cut the conduit A U L listed conduit connector must be provided at the junction box Do not ground to a gas pipe Do not have a fuse in the grounding or neutra...

Page 2: ... diagrams for illustration purposes only II JI II JI 5 8 13 16 16 20 mm Ensure the cavity is completely sealed with no gaps Ensure the cavity is completely sealed with no gaps 1 8 2 5 mm 5 8 13 16 16 20 mm 1 8 2 5 mm Product and cabinetry dimensions inches mm WOUD230 WODU30 models A overall height of product 48 7 16 1230 B overall width of product 29 757 C overall depth of product without handle 2...

Page 3: ...codes DO NOT PERMIT connecting the cabinet grounding conductor to the neutral white wire in junction box 7b Separate the factory taped green and white oven cable wires 8b Connect the white oven cable wire to the neutral white wire in junction box 9b Connect the green grounding oven cable wire to a grounded wire in the junction box 10bReplace the junction box cover OR If connecting to a four wire e...

Page 4: ...hould come on After five minutes open the oven door and the air inside should feel warm and the top element should be glowing red Turn both the oven function knob and oven temperature knob back to OFF and repeat for the other oven if the appliance is a double model 8 TROUBLESHOOTING If the appliance is not functioning correctly after installation check the following Check that the circuit breaker ...

Page 5: ...ble de supporter le poids de l appareil le comptoir et la cavité du four sont d aplomb et de niveau et sont de la dimension prescrite la hauteur depuis le plancher est adaptée à l utilisateur la porte du four peut s ouvrir entièrement sans obstruction Exigences électriques Utilisez uniquement des conducteurs en cuivre Ne coupez pas le conduit Un connecteur homologué UL doit être installé dans la b...

Page 6: ...f seulement II JI II JI 5 8 13 16 po 16 20 mm Assurez vous que la cavité est entièrement scellée et qu elle ne présente aucun dégagement Assurez vous que la cavité est entièrement scellée et qu elle ne présente aucun dégagement Dimensions de l appareil et du module po mm Modèles WODU30 WOUD230 A Hauteur hors tout de l appareil 48 7 16 1 230 B Largeur hors tout de l appareil 29 757 C Profondeur hor...

Page 7: ...ermettent de raccorder le conducteur de mise à la terre du module au fil blanc neutre de la boîte de jonction 7b Séparez les fils vert et blanc du four qui ont été sertis en usine 8b Raccordez le fil blanc du four au fil blanc neutre de la boîte de jonction 9b Raccordez le fil de mise à la terre du four fil vert au fil de mise à la terre de la boîte de jonction 10bRemettez le couvercle de la boîte...

Page 8: ...oit s être réchauffé et l élément supérieur du four doit être rouge Tournez les boutons de fonction du four et de réglage de la température à OFF Arrêt puis répétez la même procédure pour l autre four modèle double 8 DÉPANNAGE Si l appareil ne fonctionne pas correctement après l installation vérifiez les points suivants Assurez vous que le disjoncteur ne s est pas déclenché ou que le fusible n est...

Reviews: