background image

9

GAS CONNECTION

Connection: 

1/2” NPT male with 3/8” flare adapter

 Operating pressure:

 4.0” W.C. 

Supply pressure: 

5” to 14” W.C. If in excess of 14” W.C. a step down regulator is required.

Check with your local gas utility company or local codes for instructions on installing gas 
supply lines. Be sure to check on type and size of run, and how deep to bury the line. If the 
gas line is too small, the griddle will not function properly. .

Connecting the fittings supplied with the double side burner/griddle.

Use joint compound on male threads only. Do not use joint compound on the flare end of the 
1/2” NPT to 3/8” flare adapter. Ensure that the regulator arrow points in the direction of gas 
flow towards the unit, away from the supply. Do not forget to place the installer-supplied gas 
valve in an accessible location.

base of product
open top manifold

1/2” coupling

1/2” NPT x 2.0 nipple

1/2” NPT to 3/8” 

flare adapter

to gas supply

1/2” NPT x 5.0 nipple

Regulator

Verify the type of gas supply to be used, either natural or LP, and make sure the marking 
on the appliance rating plate agrees with that of the supply. The rating plate is located on 
the underside of the drip tray. Never connect an unregulated gas line to the appliance. You 
must use a gas regulator even if the supply is controlled.
Gas conversion kits are available from Customer Care. When ordering gas conversion kits, 
have the model number, and the type of gas (natural or LP) from your side burner/griddle.
The appliance and its individual shut-off valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at test pressures in excess of 
1/2 PSIG (3.5 kPa.). The appliance must be isolated from the gas supply piping system by 
closing its individual manual shut-off valve during any pressure testing of the gas supply 
piping system at test pressures equal to or less than 1/2 PSIG (3.5 kPa.). The installation 
of this appliance must conform with local codes or, in the absence of local codes, with the 
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
Installation in Canada must be in accordance with Natural Gas and Propane Installation 
Code, CSA B149.1, and/or Propane Storage and Handling Code, B149.2 and local codes.

z

z

Note:

z

z

If it is evident there is excessive abrasion or wear, or the hose is cut, it must be 

replaced prior to the outdoor cooking gas appliance being put into operation. 

z

z

The replacement hose assembly shall be that specified by the manufacturer. 

Total gas consumption of the double side burner/griddle with all burners on HI.
GDSBE1-30:

 49,000 Btu/hr

GAS REQUIREMENTS

NATURAL GAS CONNECTION

Summary of Contents for DCS GDSBE1-30

Page 1: ...GDSBE1 30 Models DOUBLE SIDE BURNER GRIDDLE INSTALLATION GUIDE US CA 592076A 11 19...

Page 2: ...unded power outlet Never remove the grounding plug or use with a 2 prong adapter Use only extension cords with a 3 prong grounding plug rated for the power of the equipment and approved for outdoor us...

Page 3: ...reduce the risk of fire injury to persons or damage when using the appliance follow the important safety instructions listed below Read all the guidance before using the appliance Do not use an outdo...

Page 4: ...t with this outdoor cooking gas appliance z z Unplug from the outlet when not in use and before cleaning Allow to cool before putting on or taking off parts z z Do not operate the appliance with a dam...

Page 5: ...Overall depth excluding dials 26 7 8 683 D Depth of chassis 22 5 8 574 E Width of chassis including support brackets 27 13 16 707 F Height below countertop 9 15 16 252 G Height of surface above counte...

Page 6: ...re to wind proximity to traffic paths and keeping any gas supply lines as short as possible Locate the unit in a well ventilated area The counter and supporting ledges or deck must be level and flat T...

Page 7: ...aster The side burner griddle is designed for easy placement into built in masonry enclosures For non combustible applications the unit drops into the opening and hangs from its side flanges A deck is...

Page 8: ...d or plastered Do not use this appliance under unprotected overhead combustible surfaces Insulated jacket If the side burner griddle is to be placed into a combustible enclosure an approved insulated...

Page 9: ...power transformer to operate the products ignition and dial illumination features The transformer is sealed in a box with an attached power supply cord ELECTRICAL CONNECTION TO OUTLET Dial halos When...

Page 10: ...to the appliance You must use a gas regulator even if the supply is controlled Gas conversion kits are available from Customer Care When ordering gas conversion kits have the model number and the type...

Page 11: ...e LP tank into the tank retention device as shown in the cart installation guide Insert the regulator inlet into the tank valve and turn the black coupler clockwise until it tightens Do not over tight...

Page 12: ...applying the solution around the connection tubing and end of the manifold Soap bubbles will appear where a leak is present A complete gas tightness check must be performed at the installation site Pe...

Page 13: ...HI Hold for 10 seconds to light the selected burner Turn the control dial counter clockwise to the lowest setting BEZEL FRONT VIEW The valves on the double side burner griddle unit feature an adjusta...

Page 14: ...to page 9 for gas connection advice Remove the support brackets from the sides of the unit and replace with the supplied cart mount brackets Remove the drip pan and any other removable components fro...

Page 15: ...ent burner lit the pressure regulator is connected and set for 4 0 W C Natural 11 0 W C LP gas the manual shut off valve is installed and accessible the unit has been tested and is free of leaks the u...

Page 16: ...ions in this document apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should...