6
CLEARANCE SPECIFICATIONS
Make sure the heater is level.
Note: The stated clearance to combustibles represents a surface temperature of 90°F
(32°C) above room temperature. Building materials with a low heat tolerance (such
as plastics, vinyl siding, canvas, tri-ply, etc.) may be subject to degradation at lower
temperatures. It is the installer’s responsibility to assure that adjacent materials are
protected from degradation. Stainless steel hardware is highly recommended. Bolts in the
wall should be secured to the wall studs/structure. Weight of the heater is 50 lbs.
0° and 45° Installation
Minimum clearances to
combustible and non-combustible
material:
FRONT
Heater mounting
body assembly
min 18"
min 18"
48"
min 96"
Non-combustible surface* (required)
Combustible surface
Flooring
Non-combustible surface*
or combustible surface