Fisher & Paykel CG752D Installation Manual Download Page 7

6

FRONT

ISO

CLEARANCE DIMENSIONS

CG301D

CG302D

CG451D

CG603D

CG604D

CG752D

CG903D

CG905D

mm

mm

mm

mm

mm

mm

mm

mm

A

Minimum clearance from left edge of cutout to nearest combustible surface

120

120

60

115

130

115

115

130

B

Minimum clearance from right edge of cutout to nearest combustible surface

120

120

60

115

115

115

115

115

C

Minimum clearance from rear edge of cutout to:
  Nearest combustible surface
  Nearest non-combustible surface

85
45

160

45

85
45

160

45

160

45

125

45

125

45

160

45

D

Minimum height of non-combustible material when used on adjacent walls

150

150

150

150

150

150

150

150

E

Minimum clearance from cooktop surface to:
  Rangehood
  Any other overhead exhaust fan
  Downward facing combustible surface
  Downwards-facing tiled or fire resistant surface

650

800

650

500

650

800

650

500

650

800

650

500

650

800

650

500

650

800

650

500

650

800

650

500

650

800

650

500

650

800

650

500

F

Minimum clearance below top of benchtop to:
  Combustible surface
  Fisher & paykel oven or nearest non-combustible surface

70
65

70
65

70
65

70
65

70
65

70
65

70
65

70
65

G

Minimum distance from right edge of cooktop to gas connection point on wall 
(if using a flexible hose)

250

250

250

250

250

250

250

250

H

Distance from floor to gas connection point on wall (if using a flexible hose)

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

min. 800 -

max. 850

I

Maximum overall depth of overhead cabinetry

600

600

600

600

600

600

600

600

Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of the product, on the right-
hand side. It should be accessible with the product installed.

5

   CLEARANCE DIMENSIONS

E

H

D

F

G

A

I

B

C

Summary of Contents for CG752D

Page 1: ...GAS ON GLASS COOKTOP CG301D CG302D CG451D CG603D CG604D CG752D CG903D CG905D models INSTALLATION GUIDE NZ AU 590149I 03 18 ...

Page 2: ...ble 900 mm from the centre rear of the product This must be accessible after installation The power supply cable should not touch any metal parts if the power supply cable is damaged it is replaced only by the special cable Part no 534993 KIT SPARES TRMNL BLK FLEX 10 obtainable from authorised Fisher Paykel Service Agents the supply connection point gas shut off valve is accessible after installat...

Page 3: ...in separate cutouts with a minimum 5mm space between the glass edges of the adjacent products If installing multiple products adjacent to each other within the same cutout a separate joining strip kit is required for installation The kit is available from the nearest Fisher Paykel Authorised Service Centre or our website listed at the end of this document If installing different products adjacent ...

Page 4: ... CG302D CG301D CG451D CG604D CG905D CG903D CG752D SEMI RAPID SEMI RAPID SEMI RAPID SEMI RAPID SEMI RAPID SEMI RAPID SEMI RAPID SEMI RAPID MINI WOK RAPID DUAL WOK DUAL WOK DUAL WOK DUAL WOK DUAL WOK DUAL WOK DUAL WOK DUAL WOK AUX AUX AUX ...

Page 5: ... 00 kPa 1 45 1 45 0 70 21 50 1 00 5 00 1 35 8 80 1 43 1 43 0 70 21 0 1 30 8 40 1 26 1 26 0 70 16 60 ULPG 2 75 kPa 0 80 0 80 0 50 20 50 0 64 5 00 0 80 8 10 0 80 0 80 0 50 20 50 0 76 7 50 0 73 0 73 0 50 16 80 GAS TYPE CG604D CG752D CG903D CG905D AUX SEMI RAPID RAPID MINI WOK DUAL WOK Jet size mm Nominal rating MJ h Jet size mm Nominal rating MJ h Jet size mm Nominal rating MJ h Jet size mm Nominal r...

Page 6: ...0 900 900 C Overall depth of product 530 530 530 530 530 450 450 530 D Height of chassis below top of bench 59 59 59 59 59 59 59 59 E Width of chassis 256 256 406 555 555 706 856 856 F Depth of chassis 486 486 486 486 486 410 410 486 G Overall width of cutout 260 260 415 560 560 715 865 865 H Overall depth of cutout 490 490 490 490 490 410 410 490 I Corner radius of cutout max 10 max 10 max 10 max...

Page 7: ...650 800 650 500 650 800 650 500 650 800 650 500 650 800 650 500 650 800 650 500 F Minimum clearance below top of benchtop to Combustible surface Fisher paykel oven or nearest non combustible surface 70 65 70 65 70 65 70 65 70 65 70 65 70 65 70 65 G Minimum distance from right edge of cooktop to gas connection point on wall if using a flexible hose 250 250 250 250 250 250 250 250 H Distance from fl...

Page 8: ...490 490 490 490 410 410 490 I Corner radius of cutout max 10 max 10 max 10 max 10 max 10 max 10 max 10 max 10 J Corner radius of routered recess max 2 max 2 max 2 max 2 max 2 max 2 max 2 max 2 K Height of routered recess 5 5 5 5 5 5 5 5 L Distance from top of bench to centre of gas inlet on product 35 35 35 35 35 35 35 35 M Distance from edge of chassis to gas inlet on product 21 21 21 21 21 21 21...

Page 9: ...re silicone does not leak underneath the glass A ROUTER THE BENCHTOP TO THE SPECIFIED DEPTH D APPLY SILICONE B FIT THE CLAMPING BRACKETS E WIPE OFF EXCESS SILICONE C MASK OFF THE AREA TO BE SILICONED F IF REMOVING PRODUCT CUT AROUND THE SILICONE 3 mm view from below Choose most appropriate slot for benchtop ...

Page 10: ...IT THE ELBOW AND WASHER 8 REMOVE THE TWO TRANSIT SCREWS 0 LOWER GENTLY INTO THE CUTOUT Recycle responsibly Model may vary from illustrations shown Repeat on the other side Floating nut Fibre washer Elbow 1 2 BSP external thread ...

Page 11: ...ersoperatingat highestsetting Ensurethehoseislongenoughtoallowforremovalofcooktopforservicing Makesuretheconnectorislocatedasshowninstep5CLEARANCEDIMENSIONS ThehoseassemblymustbeAS NZS1869ClassBorDcertified withanRp ISO7 1 femalethreadconnection Thehoseassemblymustbe nolongerthan1 2minlengthwithminimuminternal diameterof10mmandcomplywithrelevantAS5601 NZS5261requirements Thehosemustnotbekinked sub...

Page 12: ...then all burners in combination Check for a well defined blue flame without any yellow tipping If any abnormality is evident check that the components of the burner assembly are located properly If proper operation cannot be obtained contact Customer Care or your nearest F P Authorized Service Center The cooktop must not be used by the customer until proper operation has been achieved Ensure the p...

Page 13: ...e correct working pressure Have you affixed the supplied duplicate data plate label on an adjacent surface accessible to the customer Is the cooktop earthed Check that the power supply cord is NOT touching the cooktop OPERATION Do all burners ignite both individually and in combination Are the flames consistent and appropriately sized Have you demonstrated the basic operation to the customer Compl...

Page 14: ...13 ...

Page 15: ...14 ...

Page 16: ...ations in this booklet apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available ...