![Fisher & Paykel CG752D Installation Manual Download Page 5](http://html.mh-extra.com/html/fisher-and-paykel/cg752d/cg752d_installation-manual_2295006005.webp)
4
3
GAS RATE SUMMARY
All appliances are factory set for either Natural Gas or ULPG and are not convertible.
Check the ‘Gas type’ sticker on the base of the appliance.
GAS TYPE
CG301D
CG302D
CG451D
CG603D
DUAL WOK
AUX
SEMI-RAPID
DUAL WOK
SEMI-RAPID
DUAL WOK
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
NG
(1.00 kPa)*
1.45
1.45
0.70
21.50
1.00
5.00
1.35
8.80
1.43
1.43
0.70
21.0
1.30
8.40
1.26
1.26
0.70
16.60
ULPG
(2.75 kPa)*
0.80
0.80
0.50
20.50
0.64
5.00
0.80
8.10
0.80
0.80
0.50
20.50
0.76
7.50
0.73
0.73
0.50
16.80
GAS TYPE
CG604D CG752D CG903D CG905D
AUX
SEMI-RAPID
RAPID
MINI WOK
DUAL WOK
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
Jet size
(mm)
Nominal
rating
(MJ/h)
NG
(1.00 kPa)*
0.85
3.60
1.30
8.30
1.55
11.50
1.55
11.70
1.30
1.30
0.70
18.00
ULPG
(2.75 kPa)*
0.55
3.60
0.76
7.50
0.94
11.50
0.94
11.70
0.76
0.76
0.50
18.00
*Nominal pressure with at least one large burner on High.