5
GB
a
e
c
d
b
f
g
Clearances
a
>600mm from top of cooktop to downward facing combustable surface (>450mm if
protected by tiles or fire resistant materials)
b
>600mm from top of cooktop to downward facing combustable surface (>450mm if
protected by tiles or fire resistant materials)
CG603
CG903
CG913
c
side clearance from edge of product
130mm
120mm
80mm
d
rear clearance from edge of product
100mm
90mm
90mm
clearance below benchtop to any combustible
surface
10mm
10mm
10mm
e
clearance below benchtop to any combustible
surface
60mm
60mm
81mm
clearance below benchtop to F&P DishDrawer®
or F&P oven
45mm
45mm
81mm
f
Ensure there is an earthed power outlet within 900mm of the rear right-hand corner of the
product.
When used with a flexible hose, the connector on the wall should be between 800mm to
850mm above the floor and in the region outside the width of the appliance to a distance of
250mm. This should be accessible with the appliance installed.
Where the distance from the edge of the cooktop to the nearest vertical combustible surface
is less than
c
or
d
the surface must be protected in accordance with clause 5.12.1.2 of EN30.1
DOMESTIC COOKING APPLIANCES BURNING GAS FUEL to a height
g
of no less than 150mm
above the hob for the full dimension (width or depth) of the cooking surface area.
Summary of Contents for CG603 SERIES
Page 82: ...82...
Page 83: ...83 GR 1 bar...
Page 86: ...86 3 mm 900 mm 220V 240V 50Hz...
Page 87: ...87 GR 1 2 BSP 900 1 125 mm K 1 bar 20 5 100 5 10 50 11 5 10 15 mm 50 mm...
Page 89: ...89 GR 2 5 x 45 1 2 3 G20 G25 3 3 G30 G31 3 4 5 6 1 3 11 4 5 2...
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......