- 8 -
c)
Window Venting
A flexible hose is used to vent the dryer
through a window. Suitable for floor mounted
dryers only.
Internal Venting -
The dryer is provided with a vent deflector
which screws on to the back of the dryer over
the exhaust outlet.
THE DEFLECTOR MUST
BE FITTED IF EXTERNAL VENTING IS
NOT POSSIBLE.
The deflector also
prevents the dryer from being pushed against
the wall and restricting the airflow.
Custom Venting
A vent system up to 5 metres long using no
more than 3 right angle bends of at least 80,
diameter galvanised metal pipe.
External Venting
All external-venting systems should be
Made from galvanised metal pipe or be
sleeved with a galvanised metal pope where
the vent system goes through a wall or
ceiling.
Exhausted outside and not into another
confined space.
Fitted with a cap outside to stop rainwater
entering the dryer exhaust system and angled
to avoid condensation running back into the
dryer.
DO NOT use internal Vent Deflector as a
weather cap as this will cause airflow
restriction and loss in performance
Venting Duct to Existing Flush Venting
Options shown can be for both inverted or
upright dryers.