- 18 -
Stage M – To Remove Timer
(AD55 only)
Complete Stages A, B C & E then:
1. Remove 2 screws securing timer to front
of cabinet.
2. Wiring can now be removed from timer
terminations.
Reassemble in reverse order.
Stage N – To Remove Electronic
Module (ED55/56 only)
Use wrist strap and take standard ESD
precautions.
1. Complete Stage B
2. Gain access to module fixing screw by
moving protective covering.
3. Disconnect sensor plugs.
4. Disconnect wiring harness.
5. Remove three lower retaining screws
holding module to control panel.
6. Remove three upper nuts holding module
to control panel.
7. Module may now be withdrawn.
Reassemble in reverse order.
Stage O – To Remove the Door
Assembly
1. Open
door
fully.
2. Remove 2 screws retaining door hinge
cover, which can now be removed.
3. Support door with one hand, then remove
screw retaining lower hinge.
4. Door assembly may now be lifted off top
hinge. Note the location of spacer
washers.
Reassemble in reverse order.
Stage P – To Remove Door
Switch
1. Open
door
fully.
2. Remove 2 screws retaining door hinge
cover, which can now be removed.
3. Remove 2 screws retaining door micro
switch cover, which can now be removed.
4. Disconnect wiring to door micro switch – it
can now be removed.
Reassemble in reverse order, adjusting
location of switch clamp. Supply to motor
must be off when door opening is more than
40 – 65mm.
TOOLS & EQUIPMENT -
(AD/ED 55/56)
•
Ampere Meter (10-amp max) or Watt
meter. (2000 watt max)
•
Multi Meter with voltage range up to 250
V ac and resistance range up to 300 ohm.
•
Philips No.2 screwdriver.
•
6mm socket.
•
Long nose pliers.
•
Anti static wrist strap.