14.2.13
Cooling water in combustion chamber.
1. Turn generator „OFF“ at control panel.
2. Remove the glow plug (see Farymann-manual).
3. Rotate the motor by hand carefully.
4. Check if there is water in the oil and change both oil
and filter if necessary.
5. Determine cause for excess water in the combustion
chamber. The excess water can be caused by a
defective air vent in the cooling water system, which
should be checked and cleaned, or replaced if faulty.
MOTOR SPEED DROPS
Cause
Solution
Lack of fuel
Check fuel supply system:
- fuel filter, renew if necessary
- check fuel pump
- check fuel lines (bleed if necessary)
Lack of intake air.
Check air intake paths.
Check and clean air filter (and intake muffler if installed).
Generator overloaded by too many load.
Reduce the electrical load (switch off load).
Generator overloaded by over-energizing.
Check that the proper capacitor type is installed and that
they are connected correctly.
Defective generator (windings, bearings, or other).
Generator must be sent to manufacturer for repair of
damaged bearings or winding.
Damaged engine.
Repair of bearing damage, etc., by Farymann-Service.
MOTOR RUNS IN OFF POSITION
Cause
Solution
Fuel inlet solenoid valve or throttle shut solenoid is not
switching off.
Check wire connections to solenoid. Check valve func-
tions as in the „Fuel Solenoid Valve“ or in the throttle shut
off solenoid sections. Replace if necessary.
MOTOR STOPS BY ITSELF
Cause
Solution
Lack of fuel.
Check fuel supply system.
Excess heat in cooling system (thermo switch tripped)-
lack of cooling water. Is indicated on the remote control
panel.
Check cooling water system flow: water pump, inlet
water filter, extra heat exchanger coolant flow.
Lack of oil (oil pressure sensor tripped). Is indicated on
the remote control panel.
Check oil-level and if necessary top up.
Check motor's oil-pressure and have repaired by Fary-
mann-Service if necessary.
SOOTY, BLACK EXHAUST
Cause
Solution
MOTOR DOES ACHIEVE ENOUGH SPEED DURING STARTING PROCESS
Summary of Contents for Panda 4800i PMS
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Page 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Page 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Page 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Page 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Page 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...