General operation
Page 138 - Chapter 2: General operation
14.2.13
In the set-up menu of the controller, you can reset the service interval after performing maintenance. See “Set-up
menu” on Page 142.
2.1.3.2 Start-up mode
The start-up mode represents the transition from stand-by mode to operation mode, i.e., generator operation. By
actuating the Start/Stop button in stand-by mode, you can initiate the start-up process of the generator.
The pre-heating is the first step. During this stage, the status field at the top right of the default display screen shows
the word "PREHEAT".
Fig. 2.1.3.2-1: Default display screen during pre-heating
The pre-heating is always implemented for a duration of
10 seconds, regardless of the cylinder head temperature.
In temperatures below 0°C, the pre-heating time is always 40
seconds.
Fig. 2.1.3.2-2: Default display screen during start-up
After pre-heating, the starter is initiated, accompanied by
the text output "STARTING" in the status field of the
default display screen.
Note:
The controller will only perform one starting attempt. If
the generator could not be started, the text output
"STARTING FAILS" informs you of the failure of the
generator starting attempt.
Acknowledging the message with the cursor-up, cursor-down, or the Start/Stop button on the Panda iControl2 panel
will return the system to stand-by mode.
ATTENTION:
If there is difficulty in starting - close the seacock (Panda
Marine Generators only)
If the generator engine does not start immediately and further start attempts are necessary, then the seacock MUST
be closed (i.e. for ventilating the fuel lines ect.) The cooling water impeller pump turns automatically and draws cool-
ing water as long as the motor is turning. If the diesel motor is running, the cooling water is blown out by the exhaust
system gases. The cooling water cannot be pressed through the exhaust as long as the diesel motor does not run at
sufficient speed. This leads to severe motor damage.
Open the sea valve as soon as the generator is started.
Summary of Contents for Panda 4800i PMS
Page 36: ...Seite Page 36 Panda_5000i_PVMV N_Book_eng R02 14 2 13 Leere Seite Intentionally blank Basics ...
Page 130: ...Seite Page 130 Panda_4800i PMS_eng R04 14 2 13 Leere Seite Intentionally blank Tables ...
Page 148: ...Page 148 Chapter 2 General operation 14 2 13 Intentionally left blank General operation ...
Page 156: ...Page 156 Chapter 3 Installation 14 2 13 Intentionally left blank Installation ...
Page 158: ...Page 158 Chapter 4 Maintenance 14 2 13 Intentionally left blank Maintenance ...
Page 164: ...Page 164 Chapter 6 Annex 14 2 13 Intentionally left blank Annex ...