Maintenance Instructions
Seite/Page 74 - Kaptitel/Chapter 6: Maintenance Instructions
23.3.18
5. Wipe off the oil dipstick and put it into the check rail.
6. Pull the oil dipstick out of the check rail and check the oil-level. See section 6.7, “Checking oil-level,” on page 72.
If oil-level is still too low (under 2/3): repeat steps 4-6.
6.7.2 After the oil level check and refilling the oil
• Screw the oil dipstick back into the check rail.
• Close the oil filling cap.
• Remove potential oil stains and splashes from the generator and surroundings.
• Close the generator casing.
• Remove lock against accidental generator start.
6.8
Replacement of engine oil and engine oil filter
You require:
- Engine oil. See attachment.
- New oil filter (not with generators with EA300
engines)
- Sealing for oil drain screw
- Personal protective gear
- Container to collect used oil (heat resistant and
of sufficient size)
- Open-ended wrench for oil drain screw
- Paper towels and cloth
- Oil filter wrench
- Oil resistant mat, so prevent used oil from
getting into underground water
The generator must be placed at level.
• with marine generators: Change the oil when the ship is not lop-sided.
Run the generator till the engine temperature reach 60°C to ensure that the engine is warm.
Caution: Burn hazard!
Generator and coolant can be hot during and after
operating.
Wear personal protective equipment. (Gloves, protective
goggles, protective clothing and safety shoes)
1. Prepare generator.
- Assure generator against accidental start.
- Open the generator casing.
- Release the oil drain hose from the mounting.
Place an oil resistant mat under the oil drain hose area and prepare the container.