background image

Option 2:

 Key on/off five times or remote valet (Lock + Trunk for 0.5 seconds) – key does not need to be in the on 

position. 

1-11 

Open Door Notification 

– With this option the CM-230

5

 will notify the user if they try to arm their 

vehicle while a door or trunk is open. The user will receive 3 or 4 chirps and parking light flashes 
when they try to arm/lock their vehicle. You may turn this feature off with setting 2. 

1-12 

Factory Alarm Option

 - This feature controls the alarm features in the CM-230

5

 and is set by 

default to on. If you want to use the CM-

2305

 for keyless only, change the option setting to off. 

1-13 

Siren/Horn Mute Control on Remote 

– This Feature controls whether the remote can mute the

Siren or Horn from the remote and is set by default to disabled. This will not allow you to mute 
the audible output from the CM-

2305

 by remote. If you want to control the mute feature from the 

remote enable this feature. 

2-01 

Horn Output

 – This option sets the behavior of the horn wire during alarm state, during double 

lock from the remote or during lock and unlock from the remote. During one of the options the 
event will send a negative pulse on the white wire on CN3.

 

2-02 

Horn Honk

 – This option sets the duration of the output on the horn (white) wire. At default it will 

pulse depending on option 2-01. At the optional setting it will latch a ground trigger to use for 
triggering another siren.

 

2-03 

Ground When Armed

 – Ground When Armed or GWA, at default setting, will send a constant 

latched negative output when armed on the blue wire on CN3. This is used to trigger your starter 
kill relay. The optional settings change how long the GWA will send a trigger. Optional setting 4 
will make the blue wire an Auxiliary 4 which is programmable by your OP500 Option Programmer. 

2-04 

Dome Light Output

 - This option sets the timing output of the Dome Light (violet) wire on CN3. 

Default 1: 

This is a combination of 2 and 3. 

Option 2:

 Factory Rearm – This system will pulse the dome light output during lock/arm.   

Option 3:

 45 second Dome Light Output – activates the dome light for 45 seconds upon unlock/disarm. 

Option 4:

 Off 

2-05 

Unlock/Disarm With Trunk Release 

– This option has 4 settings. The settings are self 

explanatory but option 4 turns the trunk release wire (violet/white) on CN2 into an Auxiliary 3 
which is also programmable via the OP500. 

2-06 

Trunk Output Timing

 – This option sets the output duration of the violet/white wire on CN2. The 

available options are 1, 0.5, and 2 seconds. You must set the fourth option if you have option 2-
05 on setting 4. 

2-07 

Secure Aux Output

 – On the default setting, trunk and star buttons must be held for 2.5 seconds 

before Aux 1 or Aux 2 can be triggered while the CM-

2305

 is Armed and Locked. If the 

CM-

2305

 is unlocked then just press and release the Aux buttons for normal function. If you 

want this feature on all the time, change to optional setting 2. This prevents accidental triggering 
of the outputs if the CM-

2305

 is Locked or Unlocked. You can turn Secure Aux off by changing 

to optional setting 3. 

2-08 

Aux 1 Output

  - This option determines the duration of the Aux 1 output. Setting 4 allows the 

output duration to be set for a specific length of time. 

2-09 

Aux 2 Output

  - This option determines the duration of the Aux 2 output. Setting 4 allows the 

output duration to be set for a specific length of time. 

14

2-10 

Aux 1 Output Control 

– This option sets the condition which controls Auxiliary 1 and how it is 

triggered. Please see the option table for details. 

2-11 

Aux 2 Output Control 

- This option sets the condition which controls Auxiliary 2 and how it is 

triggered. Please see the option table for details. 

2-12 

Auxiliary Input 1

 – This option changes the input condition on the gray/white wire on CN3. 

Default 1: 

Will pre-warn with a negative (-) ground input. 

Option 2:

 Will arm the system with a negative (-) ground input. Used when adding an alarm to a factory keyless entry 

system. 

Option 3:

 Turns the wire into a closed loop trigger. Can be used to detect if the circuit is broken like for a trailer 

connected to the truck hitch. 

Option 4:

 Turns the wire into a (-) ignition input that bypasses the instant trigger wire and shock sensor. 

2-13 

Auxiliary Input 2

 – This option changes the input condition on the black/white wire on CN3. 

Default 1:

. Will instant trigger with a negative (-) ground input. 

Option 2:

 Will disarm the alarm with a negative (-) ground input. Used when adding an alarm to a factory keyless entry 

system. 

Option 3:

 Turns the wire into a (-) Key Sense wire. If the wire sees a negative trigger it will not allow the system to arm. 

Option 4:

 Turns the wire into a (-) Drive Lock Ctrl input. If this wire sees a negative trigger and drive lock is turned on, 

the CM-

2305

 locks the doors and when ignition is turned off it will unlocks the doors. This setting and Auxiliary 2 input 

are required for ignition controlled door locks. Connecting this wire to a (-) output from a relay triggered by the vehicle’s 
foot brake is recommended for ignition controlled door lock activation.  

2-14

 

Shock Sensor Inputs

 – 

This feature gives you control of the inputs of the shock sensor port. We 

give you different configurations to use the CM-

2305

 with OEM Remote integration. 

2-15

 Aux 1 and Control for Idatalink Modules

 – This feature will control the CM-

2305

 disarm output 

to the Idatalink modules through data when using Auxiliaries for sliding doors. 

 Option Programming 

How to Program Options 

There are three ways to set options on the CM-

2305

 control module. You can use the Quick Change 

Sequence, the FT-OP500-KIT, or most Firstech remotes. The remotes include 4 or 5 button 1 and 2 Way 
remotes.

 

Quick Change From Remotes 

There are two options on the CM-

2305

 that can change without option programming. These two options 

are for common settings used in the installation bay. Double Pulse Unlock and the Siren/Horn Mute 
options can be changed using the feature sequence below. 

Option 1-02: Double Pulse Unlock

 

Used to set Double Pulse Unlock (ONLY)  
1)  Open the Vehicle Door
2)  Turn on Ignition ( within 5 seconds )
3)  Press and Release the Trunk Button
4)  Press and Release the Star Button 
5)  Press and Release the Trunk Button 
6)  You will see 2 Parking light flashes to indicate feature change 1- 02 to Unlock. 

15

Summary of Contents for CM-2305A

Page 1: ...mente aprobados por la parte res p onsable del cum p limiento p ueden anular la autoridad del usuario p ara utilizar este dis p ositivo techfeed compustar com Installation Manual By Firstech LLC Versi...

Page 2: ...hasing a Firstech alarm keyless sy Thank you for purchasing a Firstech alarm keyless system for your vehicle The following installation stem for your vehicle The following installation manual is inten...

Page 3: ...w the instructions below IMPORTANT The remotes are preprogrammed to the control module In the event that you need to program the remotes follow the instructions below Programming the Remotes Programmi...

Page 4: ...s The parking lights will flash once to confirm the system is in valet mode Shortly after the first flash the parking lights will flash twice Jumper Settings Caution Jumper settings affect the polarit...

Page 5: ...gative output This is an optional output that will release the trunk System will unlock doors and disarm alarm prior to trunk release Pin 3 Orange Black 2nd Pulse Unlock wire This wire is used to prov...

Page 6: ...ister port Pin 1 Black L E D negative ground Pin 2 Black White L E D 3V positive output Connector 6 CN6 4 Pin Antenna Cable Pin 1 Yellow RX input This wire receives the signal from remote Pin 2 White...

Page 7: ...me vehicles This option can be changed to optional setting 2 by the remote Please see page 16 for details 1 03 Driver s Priority Unlock This lets you use the CM 2305 to unlock the driver s door before...

Page 8: ...y changing to optional setting 3 2 08 Aux 1 Output This option determines the duration of the Aux 1 output Setting 4 allows the output duration to be set for a specific length of time 2 09 Aux 2 Outpu...

Page 9: ...nds Tap Key Button Wait for corresponding parking light flash and or siren chirp before selecting option Tap Lock Button Tap Unlock Button Hold Trunk Button for 3 seconds Tap Star Button 16 Option Men...

Page 10: ...st have an Option Programmer OP500 to set a specific time output for the auxiliaries Please see the Option Tables in this manual for details The vehicle will lock and unlock but will not flash the par...