Feature
Default
Setting- I
Optional
Setting - II
Optional
Setting - III
Optional
Setting - IV
2-01
Horn
Output
On Double
Lock
On Lock and
Unlock
Alarm Only
2-02
Horn Honk
Pulsed
Latched
2-03
(-) Ground When Armed
Latched when
armed
0.5 sec
20 Seconds
Program
→
Aux 4
2-04
Dome Light Output
Factory
Rearm + 45
sec
Factory
Rearm
45 Seconds
Off
2-05
Unlock/Disarm with Trunk
Release
Unlock,
Factory
Disarm, and
Trunk Release
Factory
Disarm, Trunk
Release Only
Trunk Release
Only
Aux 3
2-06
Trunk Output Timing
1 sec
0.5 sec
2 sec
Program
→
Aux 3
2-07
Secure Aux Output
On While
Armed
On
Off
2-08
Aux 1 Output
0.5 sec
Latched
20 Seconds
Program
2-09
Aux 2 Output
0.5 sec
Latched
60 Seconds
Program
2-10
Aux 1 Output Control
By Remote
Arm
Disarm
Ignition Off
2-11
Aux 2 Output Control
By Remote
Arm
Disarm
Panic
2-12
Auxiliary Input 1
(-) Pre-Warn
(-) Arm
(-) Closed
Loop
(-) Ignition,
Instant Trigger
& Shock
Sensor
Bypass
2-13
Auxiliary Input 2**
(-) Trigger
(-) Disarm
(-) Key Sense
(-) Drive Lock
Control**
2-14
Shock Sensor Input
1st Input -
Prewarn | 2nd
Input - Trigger
1st Input -
Disable
Arm/Disarm |
2nd Input -
Trigger
1st Input -
Prewarn | 2nd
Input - Disable
Arm/Disarm
2-15
Aux 1 and Aux 2 Control
for iDatalink Modules*
(Sliding Doors)
Off
Unlock,
Factory
Disarm, and
Sliding Door
Control
Factory
Disarm and
Sliding Door
Control Only
Special Option Group
Feature
Setting Value
1
AUX 1 Output Time
1 - 100 seconds
2
AUX 2 Output Time
1 - 100 seconds
3
AUX 3 Output Time
1 - 100 seconds
4
AUX 4 Output Time
1 - 100 seconds
12
*Once programmed, this feature requires activation from the remote. Please refer to the
remote user manual or the option description below.
**This input is required for ignition controlled door locks.
Option Menu Descriptions
1-01
Lock / Unlock Pulse Duration
– This option changes the length of the lock and unlock ground
pulses on the blue and blue/black wires on CN3. The default setting is for 0.8 seconds. Optional
setting 2 changes the duration to a 2.5 second pulse. The third setting changes the duration to a
short 0.125 second pulse setting. The fourth setting changes the duration to a 3.5 second pulse.
1-02
Double Pulse Locks
– This option pulses the unlock (blue) wire twice. This will unlock all doors
and/or disarm the factory alarm on some vehicles. This option can be changed to
optional
setting 2
by the remote. Please see page 16 for details.
1-03
Driver’s Priority Unlock
– This lets you use the CM-
2305
to unlock the driver’s door before the
rest of the doors as in some factory systems. The user has the hit the unlock button on the
remote a second time to unlock the rest of the doors. The driver’s door must be isolated from the
other doors. Use the Orange/Black CN3 as your 2
nd
Unlock output.
1-04
Ignition Controlled Locks
– When you turn this option on and have the power door locks
connected the doors will lock in 30 seconds when you start the vehicle with the key. Option
setting 2 requires the (-) Drive Lock Ctrl (Aux 2 input - please see option 2-13-IV) wire connection.
When you turn the key off the doors will unlock if this feature is turned on. This feature also
requires activation from the remote. Simultaneously tap the Lock + Remote Start buttons for a
half second to activate ignition controlled door locks from the remote. The parking lights will flash
once to indicate this feature is ON.
1-05
Siren Duration
– The default setting for the siren output upon panic or alarm trigger is 30
seconds. You have the ability to extend that with this option. Please see the option tables for
other available settings.
1-06
Confirmation Chirps
– This feature controls the output of the siren wire to increase or decrease
the volume of the siren upon lock and unlock.
1-07
Auto Rearm
– The system will automatically rearm and relock if there is no activity on the (green)
ignition wire or (red/white) door trigger wires. See the option table for available settings.
1-08
Passive Arming
– This option must be set to 2 before you can turn Passive Arming on with the
remote. Passive Arming will happen only after the door is opened and closed. Simultaneously tap
the Trunk buttons on the remote for a half second to activate passive arming from the
remote. The parking lights will flash once to indicate this feature is ON.
1-09
Dome Light Delay
– This option is used when connecting the door trigger input to the vehicles
dome light circuit. It delays the door trigger input to prevent the
door open notification.
Please
see the option table for available settings.
1-10
Valet Mode
– This option changes how to enter Valet Mode with the remote.
Default 1:
Key on/off five times or remote valet (Lock + Trunk for 0.5 seconds) with key in the on position.
13