16
STEP 4:
Enter the first digit of the desired four-digit pass code by knocking on the windshield in front of
the RPS the desired number of times. For example, to enter 3, knock on the sensor 3 times (each time
you knock the LED will flash RED) then wait.
STEP 5:
The LED on the RPS will confirm your first number by flashing BLUE slowly. Once the LED
begins to flash rapidly in BLUE, enter your second number by repeating step 4.
STEP 6:
Repeat steps 4 & 5 to enter all four numbers.
STEP 7:
Turn the ignition OFF - the RPS disarm/unlock feature is now programmed. Follow steps 3 – 5
to enter your disarm/unlock code.
Secure Valet Switch
The optional Secure Valet Switch prevents the alarm from being put into valet mode through cycling the
ignition on/off five times. The Secure Valet Switch is more secure than traditional toggle / valet switches
because it requires a two-digit code.
IMPORTANT:
The first two-digits of the RPS unlock/disarm pass
code will be the default pass code for the secure valet – you do not need to program them
independently. If you are not using the RPS unlock, following the below procedures to program your
secure valet pass code;
STEP 1:
Turn on
Option 3-10-III.
(Dealer programmed option)
STEP 2:
Turn ignition key to the “on” position.
STEP 3:
Hold down the valet switch for 1.5 seconds. The LED on the valet switch will begin to flash
rapidly with successful completion of this step.
STEP 4:
Enter the first digit of the desired two-digit pass code by depressing the switch the number of
times that coordinates with the desired first number. For example, to enter 3, depress the switch 3 times,
then wait.
STEP 5:
The LED will confirm the first number by flashing BLUE slowly. Once the LED begins to flash
rapidly, enter your second number by repeating step 4.
STEP 6:
Turn the ignition off - the Secure Valet Switch is now programmed. Follow steps 3 – 5 to enter
your Secure Valet code.
Timer Start Mode
Timer start mode is used to cool or warm the vehicle without manually starting with the key or
from the CompuStar remote. While engaged, timer start will activate even while the remote is
out of range. Tap buttons
(II+IV)
simultaneously for 0.5 seconds to activate timer start mode. The
remote will beep once and the timer start icon will illuminate just above the clock icon. Repeat the same
step to turn off timer start mode. Timer start mode will be cancelled any time the vehicle is started
manually or remotely. To change from the default setting to optional settings, see your local CompuStar
dealer.
Default 1:
Will start every 3 hours for a 24 hour cycle, or until the vehicle is remote started or started by
key, and run for 4 minutes (8 minutes for diesel).
Option 2:
Will start every 1.5 hours for a 24 hour cycle, or until the vehicle is remote started or started by
key, and run for 4 minutes (8 minutes for diesel).
Option 3:
Will start at the time specified on the 2 way remote once within 24 hours and run for either 15,
25, 45 or 4 minutes (see your local dealer to change the run-time options).