background image

  

 

13 

Tap button 

(II)

 for 0.5 seconds to trigger auxiliary output 1.  Tap button 

(III)

 for 0.5 seconds to 

trigger auxiliary output 2.  The remote will beep once and the aux icon will illuminate indicating 
that the auxiliary outputs have been triggered. 
 
By default, the system is in secure auxiliary mode, which requires you to tap button 

(IV)

 for 0.5 seconds 

prior to triggering auxiliary 1 or 2.  To turn off secure auxiliary, ask your authorized CompuStar dealer to 
turn on 

Option 4-5

 to setting 

II

Temperature and Battery Query 

When in range of your vehicle, the remote will display the vehicle’s temperature, battery voltage 
and remote battery voltage upon taping button 

(IV)

.  The temperature will be displayed after 

taping button 

(IV)

 for 0.5 seconds.  Tab button 

(IV)

 a second time within four seconds to display 

the vehicle’s battery voltage.  Tab button 

(IV) 

a third time within four seconds to display the 

remote’s battery voltage.

 

 

 
If you tap button 

(IV)

 and you do not get any response from the remote, the remote pager is most likely 

out of range to receive commands. 

Silent Arm/Disarm 

Upon lock/arm and unlock/disarm, you can eliminate vehicle’s audible confirmation by muting 
the siren.  Normally, the siren will chirp once to indicate the system is locked/armed and twice 
to indicate the system is unlocked/disarmed.  To mute the siren tap buttons 

(I+II)

 simultaneously for 0.5 

seconds.  When the siren is muted, the siren icon will no longer be displayed on the LCD.  

IMPORTANT: 

Even when the siren is muted, it will still go off in the event the alarm is triggered. 

Remote Mute/Vibration Mode 

All CompuStar PRO two-way LCD remotes have the option to be muted.  To make the remote silent you 
must turn on vibration mode; 
 

STEP 1: 

Enter remote programming mode by holding down buttons 

(II + III)

 simultaneously for 2.5 

seconds.  The remote will beep once and the LCD will read “Pro9” to indicate that you have successfully 
entered programming mode. 
 

STEP 2: 

Scroll through the remote options by taping button 

(IV)

 for 0.5 seconds.  To set 

vibration mode tap button 

(IV)

 five times, or until the vibration mode icon is flashing.  If 

programming the P2WSHLCDR, simply tap button 

(IV)

 one time for 0.5 seconds after entering remote 

programming mode.  
 

STEP 3: 

Once the vibration icon is flashing, turn the feature on or off by taping button 

(I)

 for 0.5 seconds.  

Exit remote programming by holding down buttons 

(II + III)

 simultaneously for 2.5 seconds.  The remote 

will beep three times indicating that you have successfully exited programming.  The vibration icon will 
remain illuminated on the LCD indicating the remote is in remote mute/vibration mode. 

Shock Sensor On/Off 

Hold buttons 

(I+III)

 simultaneously for 2.5 seconds to turn on and off the shock sensor.  The 

remote will beep twice and the shock sensor icon will illuminate to confirm the shock sensor is 
off.  The remote will beep once and the shock sensor icon will disappear to confirm the shock 
sensor is on.  

IMPORTANT:

  Turning off the shock sensor also turns off the optional sensor. 

 
 
 

Summary of Contents for CompuStar Pro P2W900FMR

Page 1: ...FCC rules Operation is subject to the following conditions 1 This device may not cause harmful interference 2 This device may accept any interference received including interference that may cause und...

Page 2: ...ervation Mode 11 Trunk Release 12 Auxiliary Outputs Window Roll Down Sliding Doors 12 Temperature and Battery Query 13 Silent Arm Disarm 13 Remote Mute Vibration Mode 13 Shock Sensor On Off 13 Advance...

Page 3: ...original place of purchase For further information you may also contact our customer support center by calling 888 820 3690 Kit s Contents Warranty Coverage Caution The Manufactures warranty will be v...

Page 4: ...art P2WSS A alarm w out remote start P2WSS S remote start w out alarm P2W9000R 2 Way 900MHz Applicable to the following models P2W9000 AS alarm and remote start P2W9000 A alarm w out remote start P2W9...

Page 5: ...Replacement The only regular maintenance this system requires is remote control battery replacement No programming is required when replacing the battery Two Way Remotes Models P2WSSR P2W9000FMR First...

Page 6: ...rns siren on off Note With the siren off it will still sound in the event the alarm is triggered I II 2 5 seconds no Option programming menu 1 For use during installation 0 5 seconds no Valet mode see...

Page 7: ...no Option programming menu 1 Installers Only 0 5 seconds no Valet mode see page 5 for details 2 5 seconds no Turns the shock sensor on off 0 5 seconds Option 1 9 Drive lock Activates ignition control...

Page 8: ...the system will be disarmed and the doors will unlock before the trunk is released Signal Strength This icon is displayed if the last communication to the vehicle was successful Valet Mode This icon...

Page 9: ...system is armed The remote will beep rapidly while displaying this icon This means that the alarm was triggered If this icon appears while trying to remote start the vehicle it means that the vehicle...

Page 10: ...e remote will auto sync if it fails communicate after 8 sending commands or more During auto sync the remote automatically and quickly transmits a lot of frequencies in search for the location of the...

Page 11: ...l beep once and the CompuGLO backlight will light up to indicate that the remote start command has been successfully transmitted If you are in range and the remote beeps three times there is a remote...

Page 12: ...rking brake after the key was removed from the ignition You entered valet mode opened the vehicles door hood trunk or set off the alarm Reservation Mode Settings Reservation mode settings can be progr...

Page 13: ...the siren icon will no longer be displayed on the LCD IMPORTANT Even when the siren is muted it will still go off in the event the alarm is triggered Remote Mute Vibration Mode All CompuStar PRO two...

Page 14: ...al transmission vehicle the doors will unlock upon setting the emergency parking brake Turbo Timer Mode The built in turbo timer keeps the vehicles engine running for either 1 2 or 4 minutes programma...

Page 15: ...RPS at least two times The switch on the RPS will adjust paging sensitivity the smaller the dot represents the least sensitive setting Use a key or pen for best results If you do not want the remote t...

Page 16: ...4 Enter the first digit of the desired two digit pass code by depressing the switch the number of times that coordinates with the desired first number For example to enter 3 depress the switch 3 times...

Page 17: ...conjunction with timer start mode see above and the temperature sensor It allows you to configure your timer start feature to check the vehicles temperature prior to starting All of these options req...

Page 18: ...for the 5th time press button I on two way remotes or the lock button on one way remotes for 0 5 seconds The parking lights will flash once to confirm the transmitter has been coded Exiting Programmi...

Page 19: ...manual transmission only 4 Trunk open 5 Foot brake on 6 Hood open 7 Reservation off manual transmission only 8 Tach or voltage sensing failure We recommend that you do not attempt any repairs on your...

Page 20: ...THEREWITH SHALL BE RESPONSIBLE OR LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO ANY CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES FOR LOSS OF TIME LOSS OF EARNINGS COMMERCIAL LOSS...

Page 21: ...______________________________________________________________ ___________________________________________________________________________________ _____________________________________________________...

Page 22: ...___________________________________________________________ ___________________________________________________________________________________ ________________________________________________________...

Page 23: ...23 www compustar com Toll Free 888 820 3690 21911 68th Ave S Kent WA 98032...

Reviews: