The  ROTOTERM  MR-TR  heating  controller  is  a  3-port  PID 

controller used for under floor or radiator heating. Via its outputs 

it controls the motor actuator for mixing valve and circulation 

pump.

Basically it controls the temperature of mixed flow in dependence 

on  exterior  tem pera ture,  deviation  of  the  required  and  actual 

room temperature and parameters set.
The controller operates according to nonlinear heating curves, 

which  enables  correct  heating  even  with  higher  exterior 

temperatures. Setting of the curve ratio is possible also from 

0,1 do 2 in resolution per 0,1 (20 curves). Parallel shift of the 

curve enable settings within the limits from -10 to +10, which 

means, that the starting points of the curves can be moved by 

+/- 10°C.
By means of the three digit display and the three keys it is possible 

to set all the parameters and to control all the temperatures. The 

display also shows all errors of the sensors (disconnection “Er1” 

and short circuit “Er2”).
The design of controller allows also operation without room unit 

AS2000-E - operating regarding selected heating curve. This is 

especially useful for under floor heating, where night reductions 

do not present any advantage, due to the system inertia.

When the controller switches over to under floor operating mode, 

it  automatically  assumes  individual  limits:  temperature  of  the 

mixed  flow  is  50°C,  setting  of  heating  curve  ratio  is  possible 

only from 0.1 - 1 and influence of the room units is possible  only 

between 0 and 5. The under floor sensor of the controller prevents 

the under floor to get too hot, thus prevents the unpleasant feeling 

of warmth in your feet.
When used with radiator version, the sensor is located into the 

boiler  in order  to prevent condensation  or overheating  of the 

boiler. In case the boiler temperature falls bellow the condensing 

temperature,  the  controller  momentarily  chokes  the  mixing 

valve, thus reducing the consumption and assuring quick and 

easy  heating  of  the  boiler  to  the  required  temperature.  If  for 

any reasons the temperature of the boiler exceeds 95°C, the 

controller opens the mixing valve, speeds up the consumption 

and prevents overheating of the boiler and cut-off of the thermal 

breaker.
The  controller  automatically  activates  the  pump,  immediately 

when heating is re quired and switches it off when the heating 

water  line  is  cooled  down  bellow  the  set  temperature.  This 

temperature can be adjusted within the range of 20°C to 45°C.
When  switched  on,  the  display  of  the  ROTOTERM  MR-TR 

controller illuminates and shows the tests of sensor, pump and 

mixing valve operation. After some 5 seconds the controller starts 

with normal operation.

TECHNICAL DATA

Supply voltage ...........................................................................................................................................................230V  , 50Hz

Power consumption ............................................................................................................................................................max. 4VA

Relay outputs...................................................................................................................................................1(1)A, 230V , 50Hz

Power consumption  ....................................................................................................................................................................4VA 

Humidity: .............................................................................................................................................5% - 70% (without condense) 

Storage temperature: .........................................................................................................................................................0°C-70°C

Mounting:  .........................................................................................................................................................................on the wall

Recommended cable use: ..............................................................................................................sensor cable:  J-Y (St) 1X 2X0,6

.............................................................................................................................................Pump, actuator cable: H03VV-F 3x0,75

Sensor type ................................................................................................................................................................PTC KTY 10-6

Temperature measuring range ....................................................................................................................................-40°C...160°C

Room temperature setting ................................................................................................................................................5°C...25°C

Program settings:

Heating curve ratio setting .......................................................................................................................................................0,1...2

Parallel shift ..........................................................................................................................................................................+/- 10°C

Room unit influence

 ..................................................................................................................................................................1...15

Controller type .............................................................................................................................................................................PID

Floor temperature limit....................................................................................................................................................15°C...35°C

Summer periodic run of pump and mixing valve ........................................................................................... every 72 hours for 30s

Connection mode ..........................................................................................................................................................terminal pins

Parameters selection mode  .......................................................................................................................................................keys

Parameters ...................................................................................................................................................... factory built-in values

Dimension of sensors:

l

l=1,5m   sensor BSF1, PVC (grey cable)

l=2m 

sensor KF, silicon (red cable)

CONTROLLER ROTOTERM  MR-TR OPERATION

Summary of Contents for 21128

Page 1: ...display Code Description 21128 ROTOTERM MR TR plus Heating controller MR TR Room unit AS 2000 E sensors AF BSVF BF mounting kit 21131 ROTOTERM MR TR Heating controller MR TR sensors AF BSVF BF mounti...

Page 2: ...t When used with radiator version the sensor is located into the boiler in order to prevent condensation or overheating of the boiler In case the boiler temperature falls bellow the condensing tempera...

Page 3: ...5 The under floor sensor of the controller prevents the under floor to get too hot thus prevents the unpleasant feeling of warmth in your feet When used with radiator version the sensor is located in...

Page 4: ...pins PIN CONNECTION 1 2 Put side air sensor AF 2000 3 4 Mixed flow sensor VF2000 grey colour 5 6 Room unit AS2000 5 9 6 9 7 8 Floor sensor BF2000 or boiler sensor KF2000 red colour 9 N Neutral condui...

Page 5: ...ltage cables 2 If the distances between sensors and controller are larger over 15 meter it is recommended the installation of VDR resistance of 25V It is installed by soldering at the point where the...

Page 6: ...se you don t have protection against floor overheating MOUNTING OF BOILER SENSOR KF 2000 for radiator heating only Mount the sensor into the cap next to the other boiler sensors In case of 4 way mixin...

Page 7: ...ars Sensor cables shall not be placed parallel to live power supply cables as in case of electric shock there is danger of induced current which can damage the controller or room unit In case that pow...

Page 8: ...fference Troom between actual room temperature and required room temperature When T2 BF KF key is pressed the display shows floor temperature or temperature in the boiler When T3 AF key is pressed the...

Page 9: ...t can be modified by means of heating curve ascent or descent Range of parallel curve shift for heating curve 1 0 SELECTION OF HEATING CURVE Heating curves represent an interconnection between outside...

Page 10: ...to This setting specifies the temperature at which the controller switches off the pump when mixing valve is already closed This function enables that all heating units are uniformly cooled down afte...

Page 11: ...value of ratio Programming is executed in three procedures For easier understanding see the diagram on the following page First procedure set the ratio of heating curve and parallel shift Second proce...

Page 12: ...Additionally it is equipped with room temperature display Room unit AS 2000 E has additional switch on the right side It makes possible to choose two heating regimes temperature control of mixed flow...

Page 13: ...inutes 10 key for setting hours 11 key for setting the day of the week 12 key for input the program 13 key RESET deletes time and program 14 Slide switch for unit operation ON temperature control of m...

Page 14: ...of operation There are two operating modes if the switch 14 in the ON position provides frost protection room temperature 8 10 C if the switch 14 in the OFF position heating is switched off closes mix...

Page 15: ...o a lower temperature On the display appears symbol which indicates switching to higher temperature 2 First switching cycle for switching to higher temperature On display appears symbol for first sett...

Page 16: ...xt switch cycle etc Temporary heating regime change Temporary change of regime is valid till next switch cycle When you re in automatic mode slide switch 2 in position AUTO press to change the regime...

Page 17: ...to position AUTO program is not set See the example of program settings the program is incorrectly configured for each switch cycle to a higher temperature is followed switch cycle to a lower temperat...

Page 18: ...T3 sensors If T2 or T3 key is pressed Er2 is displayed Sensor T2 or T3 short circuited Check T2 and T3 sensors The controller operating normally Sometimes it happens that the controller repeatedly re...

Reviews: