Operation Manual
FW-1200-M
© 2012
First Water Systems, Inc
pg. 6
Water coming from the Outlet is clean, but any down stream
distribution components may be compromised. Any components
beyond the FW-120-M should be cleaned with a 3:1 bleach solution
or other appropriate disinfectant then thoroughly rinsed before
clean water is distributed.
3.5 Operation
Once water is flowing, very little maintenance is required. Someone
should be present to monitor the following:
•
Source water does not deplete.
•
Clean water storage does not overflow.
•
Water flow does not stop.
•
Filters needing to be changed.
Pausing Operation
The FW-120-M may be turned off and on throughout an event. To
stop the flow of water, turn any downstream valves to the off
position. The pump will automatically stop. If desired, you may turn
off the power to the Filtration Unit to shut off the UV Lamp.
If the system will be down for more than 4 hours, flush with clean
water for 1 minute before turning off. Do not leave standing water in
the unit for more than 36 hours.
Resuming Operation
After a pause in operation, the system may be restarted by turning
all power back on and opening downstream valves.