4
Operation and Maintenance Safety
NEVER position the Flex-Chlorinator directly over the Chlorine Dilution
Container. The suction hose from the Chlorine Dilution Container to the
Flex-Chlorinator should fall below the top of the container, then rise back
up to the injector (see installation diagrams).
NEVER leave the Flex-Chlorinator or water lines full of water during freez-
ing temperatures. Visually inspect the Flex-Chlorinator and water system
for leakage.
Warning! Risk of Chemical Overdose
To reduce risk, follow proper installation methods and instructions. The
point of chemical injection should be beyond all pumps, filters and heat-
ers.
NEVER use chlorine with fragrance, perfume of detergent additives.
Notice:
This injection system and its components have been tested for use with
Sodium Hypochlorite (5-15%).
The Flex-Chlorinator provides a means of delivery for chemicals in gen-
eral. First Water Systems, Inc. does not suggest or recommend ways or
procedures for using any chemical.
First Water Systems, Inc. is not responsible for injury incurred by the mis-
use or improper handling of chemicals.
Specifications
Water Motor Specifications
Water Flow...................................1GPH - 13GPM
Pressure.......................................2 psi - 80 psi
Max. Temp...................................110 F (43.3 C)
Summary of Contents for Flex-Chlorinator
Page 1: ...1...