FIRST STOP SAFETY
15
Testing Class II equipment
The equipment to be tested is plugged into the mains socket on BattPAT.
The test clip is connected to any exposed metal on the equipment, if present.
Press the Class II button. If the appliance power switch is turned ON, the
green LED will be ON steady and the test will now run and the display will
show the result for the Insulation Resistance as well as an overall Pass or Fail.
If the appliance Power switch is turned OFF then the green LED will flash as
a reminder to the user. If the user turns the switch ON within 5 seconds
the test will continue and the green LED will be ON Otherwise the test will
continue after 5 seconds BUT the green LED will be OFF.
Note: On Class II appliances, such as hair driers where there is no exposed
metal, the test lead can be left unconnected.
Once the testing is complete, record the results on the Test Record.
BattPAT
Issue 2.