9
How to Adjust Regeneration Time:
1. Disconnect the power source.
2. Locate the three screws behind the manual regeneration knob by pushing the red button in and
rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration
knob.
3. Loosen each screw slightly to release the pressure on the time plate from the 24 hour gear.
4. Locate the regeneration time pointer on the inside of the 24 hour dial in the cut out.
5. Turn the time plate so the desired regeneration time aligns next to the raised arrow.
6. Push the red button in and rotate the 24 hour dial. Tighten each of the three screws.
7. Push the red button and locate the pointer one more time to ensure the desired regeneration time
is correct.
8. Reset the time of day and restore power to the unit.
FSN Series Adjustable Regeneration Time Instructions
FIGURE 6: Front of Timer Assembly (Time Clock Assembly Shown)