21
Operation Instructions
INITIAL WATER TREATMENT
Add 1 x Water Treatment Tablet per full tank. DO NOT, UNDER ANY CIRCUMSTANCE,
USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT.
Your unit purchase includes 4 x Water Treatment Tablets, which is sufficient for several
years of use. To purchase additional chlorine tabs, please consult your nearest regional
dealer/distributor or check our website at www.firstdegreefitness.com
a) Filling requires a large bucket (not supplied) and the Fluid
Rower Siphon (included). Filling will take approximately 7.6
liters of water.
b) Unscrew the yellow tank plug on tank back and insert the
flexible tube into the rear of the tank while keeping the rigid
hose in the bucket. Note: The siphon tube may be impeded
by one of the impeller blades. Use the siphon only to push
the impeller down slightly.
Note: Where water quality is known to be poor, FDF
recommends the use of distilled water.
c) Move the adjuster handle to level 16, and begin filling.
Note: The siphon valve must be closed to allow siphoning
action to occur. Tip: Placing the bucket in an elevated
position will allow the siphon to continually pump water into
the tank. Do not fill past the calibration mark indicated on
the tank!
Note: Opening the siphon valve will stop the pumping action.
Use this feature to avoid water spillage when nearing filling
completion.
d) Once filling is complete (to the proper calibration level as
indicated on the tank), follow water treatment schedule as
shown.
Note: the Lower Tank Plug is permanently sealed.
CAUTION
Use a drop cloth under
the tank when filling to
avoid damage floor or
carpet.
Do not fill past the
calibration mark as
indicated on the tank
level sticker or water
spillage may occur.
WARNING
Impeller blades are
sharp! Do not Place
fingers in tank to
adjust impeller position.
It is recommended to
use the end of the hose
Should the impeller
REQUIRED
Siphon [25]
Tank Filling and Water Treatment
Siphon valve
Fill tank as shown left. Use
the yellow plug only for filling.
Fill with adjuster handle at level
16 only.
Once filling is complete, use a
coin or large blade screwdriver
to tighten tank plug into place.
Summary of Contents for Fluid FR-E316