Firman H05753 Owner'S Manual Download Page 27

Page 25

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

If a cover is used, do not install until unit has cooled.

WARNING

Fuel and its vapors are extremely flammable and
explosive  which  could  cause  burns,  fire  or

DO NOT stop engine by moving choke control
to “

START

” position.

Important

: Always ensure that the 

 is in the “

OFF

” position when the engine 

is not in use.

fuel selector 

switch

explosion resulting in death, serious injury
and/or property damage.

If the engine will not be used for a period of two 
weeks or longer, please see the Storage section 
for proper engine and fuel storage.

NOTE

Disconnect

 

the

 

LPG

 

cylinder from the 

generator during transportation.

This  generator  is  equipped  with  an  electronic 
module  which  consumes  battery  power.  When 
the fuel selector switch is turned to the “

GAS

” or 

LPG

”  position,  the  indicator  light  will  become 

RED

 up to 

4 minutes

(before goes off).

Indicator light - Battery Power Saving Mode

The  indicator  light  will  start 

FLASHING

  for 

minutes

  in  the  event  of  any  unwanted  shutdown 

such as low oil, running out of fuel(gasoline or LPG), 
or  any other unwanted shutdown. This is a reminder 
that  the  generator  is  switching  to 

Battery  Power 

Saving  Mode.

  The  generator  should  be  checked 

Starting the engine successfully during these 

minutes

 will turn the indicator light 

GREEN

.

Starting the engine unsuccessfully or not attempting 
to start the engine at all during these 

4 minutes

 will 

switch generator to 

Battery Power Saving Mode

 in 

order  to  conserve  and  increase  the  life  of  battery.

MUST  HAVE 

SOLID  RED  INDICATOR  LIGHT 

TO 

BE ABLE TO START THE GENERATOR. THE GENERATOR 
CANNOT  BE  STARTED  DURING 

BATTERY  POWER 

SAVING MODE

 UNLESS THE FUEL SELECTOR SWITCH 

IS  TURNED  TO  THE  “

OFF

”  POSITION  AND  THEN 

TURNED BACK TO THE “

GAS

” OR “

LPG

” POSITION.

Unwanted Shutdown:

The  generator  cannot  be  started  during  or  after 
the 

4 minutes

 of 

FLASHING

 mode unless the fuel 

selector switch is turned to the "

OFF

" position and 

then turned back to the “

GAS

” or “

LPG

” position. 

for any unwanted shutdown.

This generator is equipped with an automatic 
battery  charging  circuit  and  the  battery  will 
receive  a  proper  charge  when  the  engine  is 
running to keep the battery charged.

Low Oil Shutdown

If the engine oil drops below a preset level, an 
oil switch will stop the engine. Check oil level 
with dipstick.
If oil level is between LOW and HIGH mark on 
dipstick:
1.DO NOT try to restart the engine.
2.Contact an Authorized FIRMAN Service Dealer.
3.DO NOT operate engine until oil level is 
   corrected.
If oil level is below LOW mark on dipstick:
1.Add oil to bring level to HIGH mark.
2.Restart engine and if the engine stops again 
   a low oil condition may still exist. DO NOT try 
   to restart the engine.
3.Contact an Authorized FIRMAN Service Dealer.
4.DO NOT operate engine until oil level is 
   corrected.

Do Not Overload Generator

Overloading a generator in excess of its rated 
wattage capacity can result in damage to the 
generator and to connected electrical devices.

To prolong the life of your generator and 
attached devices, follow these steps to add 
electrical load:

1. Start the generator with no electrical load 
    attached.
2. Allow the engine to run for several minutes 
    to stabilize.
3. Plug in and turn on the first item. It is best to 
    attach the item with the largest load first.
4. Allow the engine to stabilize.
5. Plug in and turn on the next item.
6. Allow the engine to stabilize.
7. Repeat steps 5-6 for each additional item.

Summary of Contents for H05753

Page 1: ...and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number DUAL FUEL GENERATOR MODEL NUMB...

Page 2: ...tion Connecting to a Building s Electrical Maintenance And Storage 27 Maintenance Schedule 27 Engine Maintenance 28 Change Engine Oil 28 Air Filter Maintenance 28 Spark Plug Maintenance 29 Cleaning Fu...

Page 3: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...OR DRAINING GASOLINE Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfi...

Page 7: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Page 8: ...Gasoline can cause a fire or explosion if ignited Gasoline is a liquid fuel but it s vapors can ignite Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes...

Page 9: ...CAUTION LPG under pressure is highly flammable and can cause a fire or explosion if ignited LPG is heavier than air and can accumulate in confined spaces and low places in the event of a leak LPG has...

Page 10: ...he axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with the cotter pin C 5 Repeat steps 2 4 to attach anoth...

Page 11: ...nnection NOTE The generator comes equiped with the positive red and negative black cables already attached to battery terminals 1 Cut wire tie that is binding the black battery cables A and B 2 Insert...

Page 12: ...OHV Engine 7 Recoil Starter 8 10 0 Flat Free Wheel 9 10 11 12 13 Oil Filler Cap Battery Outlet Cover Control Panel Handle 14 LPG Hose Connector Inlet 15 Hose Holder 16 LPG Hose with Regulator English...

Page 13: ...t will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREEN MUST HAVE SOLID RED INDICATOR LIGHT TO BE ABLE TO START TH...

Page 14: ...RMAN1 9 10 11 Outlet Cover Protect the receptacles from dust and debris LPG Hose Connector Inlet Used to connect LPG hose to generator 120 240V 30A Twist Lock NEMA L14 30R Maximum 30 Amp current maybe...

Page 15: ...1L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 5700 GASOLINE 5700 LPG FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section AN IMPORTANT MESSAGE ABOUT TEMPERATURE When...

Page 16: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an e...

Page 17: ...d fuel fill cap remove cap 2 Slowly add unleaded fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let an...

Page 18: ...ealant to seal the LPG hose connections Always position the cylinder so the connection between the valve and the regulator won t cause bends or kinks in the hose Spray a soapy water solution one part...

Page 19: ...atio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss FIRMAN can provide a hig...

Page 20: ...any Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical co...

Page 21: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Page 22: ...un at no load for few minutes upon each initial start up to permit engine and generator to stablize StartingtheGenerator RecoilStart LPG 1 Before starting the generator check for loose or missing part...

Page 23: ...EEN 6 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 7 Move choke lever located on engine to START position NOTE D...

Page 24: ...ctor switch is turned to the GAS position the indicator light will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREE...

Page 25: ...g the engine successfully during these 4 minutes will turn the indicator light GREEN 6 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plug...

Page 26: ...do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during bre...

Page 27: ...STARTED DURING BATTERY POWER SAVING MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION Unwanted Shutdown The generator cannot be started...

Page 28: ...ufficient fuel flow to the engine This is not an indication of a problem with the generator but only a problem with the flow of gas from the LPG cylinder If generator performance seems to be deteriora...

Page 29: ...hart above Notice Once a year you should clean or replace the spark plug and replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better...

Page 30: ...o cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine...

Page 31: ...ank causing a fire resulting in death or serious injury and or property Contact with muffler area could cause burns resulting in serious injury WARNING A B A Spark plug B Spark plug cap c DO NOT touch...

Page 32: ...and attach with the screws Spark arrester screen Flange Screw Battery Replacement 1 Remove the spark plug wire from spark plug 2 Remove the nut and bolt from the negative and positive posts 3 Loosen...

Page 33: ...il it stops from lack of gasoline This will dry out all remaining gasoline in tank fuel lines and carburetor 5 Turn fuel selector switch to OFF position Fully close the LPG cylinder knob if it is open...

Page 34: ...tic battery charging circuit The battery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is used on a regular basis about once every two...

Page 35: ...esh gasoline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility 12...

Page 36: ...Page 33 PARTS DIAGRAM AND PART LIST H05753 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 142 143...

Page 37: ...Page 34 439cc DUAL FUEL ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 38: ...1 1 1 1 1 7 1 1 1 1 2 2 2 1 1 8 2 2 1 FIRMAN 439cc Dual Fuel Engine NO Part Number Qty Description 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104...

Page 39: ...case Comp Bolt drain Washer drain Bolt Oil Level Sensor Flg Bolt M6 15 Bearing Locating Pins Bearing Balance Shaft Camshaft Comp Crankshaft Gear Crank Shaft Gear Drive Gskt Crankcase Cover Oil Dipstic...

Page 40: ...by this warranty Normal Wear Your product needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a w...

Page 41: ...f God and other force majeure events beyond the manufacturer s control problems caused by parts that are not original FIRMAN parts units used for prime power in place of existing utility power where u...

Page 42: ...failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on y...

Page 43: ...ld Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FI...

Page 44: ...P N 357745483 Rev 04 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6...