Firman H05753 Owner'S Manual Download Page 19

Page 17

English                                                                                                                                                  Customer Service: 1-844-FIRMAN1

3-Permanent Connection to a large 
Propane supply tank:

In  the  instance  that  you  would  need  to  connect 
your  generator  to  a  large  propane  Supply  tank, 
larger  than  20  or  30  lb  DOT  cylinder,  it  is 
recommended  to  contact  your  Gas  Equipment 
Company.  Various  equipment  for  use  with  LPG, 
is  required  for  proper  conformance  to  all  NFPA 
regulations.  Your  Gas  Equipment  Company  can 
help  you  select  and  install  the  proper  regulator, 
fittings  and  connections  to  meet  all  the  Codes 
and  manufacturer  regulations.  Each  installation 
may be different and will required proper equipment. 
Contact  your  Gas  Equipment  Company  to  assure 
that  you  are  meeting  all  NFPA  58  (Liquefied 
Petroleum  Gas  Code)  and  NFPA  54  (National  Fuel 
Gas) Codes.

Operation

 

at

 

High

 

Altitude

At altitudes over 5,000 feet(1524 meters), a 
minimum 85 octane / 85 AKI (89 RON) gasoline 
is acceptable.

The

 

density

 

of

 

air

 

at

 

high

 

altitude

 

is

 

lower

 

than

 

at

 

sea  level

Engine

 

power

 

is

 

reduced

 

as

 

the

 

air

 

mass

 

and

 

air-fuel  ratio

 

decrease

Engine

 

power

 

and

 

generator

 

output  will

 

be

 

reduced

 

approximately 3.5% for every 1000 feet

 

of

 

elevation

 

above

 

sea

 

level

This

 

is

 

a

 

natural

 

trend  and

 

cannot

 

be

 

changed

 

by

 

adjusting

 

the

 

engine

At

 

high  altitudes

 

increased

 

exhaust

 

emissions

 

can

 

also

 

result 

due

 

to

 

the

 

increased

 

enrichment

 

of

 

the

 

air

 

fuel

 

ratio

.

Other

 

high

 

altitude

 

issues

 

can

 

include

 

hard

 

starting

increased

 

fuel

 

consumption

 

and

 

s p a r k

 

p l u g

 

f o u l i n g

T o

 

a l l e v i a t e

 

h i g h

 

a l t i t u d e

 

i s s u e s

 

o t h e r

 

t h a n

 

t h e

 

n a t u r a l

power

 

loss

FIRMAN

 

can

 

provide

 

a  high

 

altitude

 

carburetor

 

main

 

jet

.

 The

 

alternative

 

The part number and recommended minimum 
altitude  for  the  application  of  the  high 
altitude  carburetor  main  jet  is  listed  in  the 
table below.

main  jet  and  installation  instructions  can  be 
obtained  by  contacting  Customer  Support. 
Installation  instructions  are  also  available  in  the 
Technical Bulletin area of the FIRMAN internet site.

Altitude main jet 1

Altitude main jet 2

439cc

380717004

380717005

Altitude

3000-6000Feet

6000-8000Feet

OPEN

WARNING

When transporting and storing, turn off the 
cylinder valve and fuel selector switch, and 
disconnect the cylinder.

Contact with liquid contents of the cylinder 
will cause freeze burns to the skin.

An LPG cylinder not connected for use shall 
not be stored in the vicinity of the generator.

Always keep the LPG cylinder in an upright 
position.

Do not subject LPG cylinder to excessive heat.

In the event of an LPG fire, flames should not 
be  extinguished  unless  by  doing  so  the  fuel 
supply  valve  can  be  turned  off.  If  the  fire  is 
extinguished and a supply of fuel is not turned 
off,  an  explosion  hazard  greater  than  the  fire 

hazard could be created. 

Keep a fire extinguisher near the generator 
all the time.

LPG has a distinctive odor to help detect 
potential leaks.

Do not allow children to tamper or play with 
the LPG cylinder.

Summary of Contents for H05753

Page 1: ...and level before performing any maintenance or service IMPORTANT Record product information to reference when ordering parts or obtaining warranty coverage Serial Number DUAL FUEL GENERATOR MODEL NUMB...

Page 2: ...tion Connecting to a Building s Electrical Maintenance And Storage 27 Maintenance Schedule 27 Engine Maintenance 28 Change Engine Oil 28 Air Filter Maintenance 28 Spark Plug Maintenance 29 Cleaning Fu...

Page 3: ...mation The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard The warnings in this manual and the tags and decals affixed to the unit are therefore not all...

Page 4: ...SAFETY PRECAUTIONS Page 02 WARNING POISONOUS GAS HAZARD English Customer Service 1 844 FIRMAN1...

Page 5: ...de and downwind far away from windows doors and vents Direct exhaust away from occupied spaces INCORRECT USAGE Do not operate in any of the following locations Near any door window or vent Garage Base...

Page 6: ...OR DRAINING GASOLINE Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap Loosen cap slowly to relieve pressure in tank Fill or drain fuel tank outdoors DO NOT overfi...

Page 7: ...T handle generator or electrical cords while standing in water while barefoot or while hands or feet are wet DO NOT allow unqualified persons or children to operate or service generator WARNING Exhaus...

Page 8: ...Gasoline can cause a fire or explosion if ignited Gasoline is a liquid fuel but it s vapors can ignite Gasoline is a skin irritant and needs to be cleaned up immediately if spilled on skin or clothes...

Page 9: ...CAUTION LPG under pressure is highly flammable and can cause a fire or explosion if ignited LPG is heavier than air and can accumulate in confined spaces and low places in the event of a leak LPG has...

Page 10: ...he axle pin A through the wheel B 3 Slide the axle pin A through the mount point on the frame and flat washer D 4 Secure the wheel and axle pin with the cotter pin C 5 Repeat steps 2 4 to attach anoth...

Page 11: ...nnection NOTE The generator comes equiped with the positive red and negative black cables already attached to battery terminals 1 Cut wire tie that is binding the black battery cables A and B 2 Insert...

Page 12: ...OHV Engine 7 Recoil Starter 8 10 0 Flat Free Wheel 9 10 11 12 13 Oil Filler Cap Battery Outlet Cover Control Panel Handle 14 LPG Hose Connector Inlet 15 Hose Holder 16 LPG Hose with Regulator English...

Page 13: ...t will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREEN MUST HAVE SOLID RED INDICATOR LIGHT TO BE ABLE TO START TH...

Page 14: ...RMAN1 9 10 11 Outlet Cover Protect the receptacles from dust and debris LPG Hose Connector Inlet Used to connect LPG hose to generator 120 240V 30A Twist Lock NEMA L14 30R Maximum 30 Amp current maybe...

Page 15: ...1L Counter Clockwise Facing P T O Float Brushed Polyurethane Type Yes 5700 GASOLINE 5700 LPG FIRMAN Rated Fequency 60Hz Oil Type See Add Engine Oil Section AN IMPORTANT MESSAGE ABOUT TEMPERATURE When...

Page 16: ...l activate a warning device or stop the engine If generator shuts off and the oil level is within specifications check to see if generator is sitting at an angle that forces oil to shift Place on an e...

Page 17: ...d fuel fill cap remove cap 2 Slowly add unleaded fuel to fuel tank Be careful not to fill above the red fuel level indicator This allows adequate space for fuel expansion 3 Install fuel cap and let an...

Page 18: ...ealant to seal the LPG hose connections Always position the cylinder so the connection between the valve and the regulator won t cause bends or kinks in the hose Spray a soapy water solution one part...

Page 19: ...atio Other high altitude issues can include hard starting increased fuel consumption and spark plug fouling To alleviate high altitude issues other than the natural power loss FIRMAN can provide a hig...

Page 20: ...any Use a ground fault circuit interrupter GFCI in any damp or highly conductive area such as metal decking or steel work DO NOT touch bare wires or receptacles DO NOT use generator with electrical co...

Page 21: ...the weather Keep exhaust pipe clear of foreign objects Keep generator away from open flame Keep generator on a stable and level surface WARNING Surge Protection Voltage fluctuation may impair the prop...

Page 22: ...un at no load for few minutes upon each initial start up to permit engine and generator to stablize StartingtheGenerator RecoilStart LPG 1 Before starting the generator check for loose or missing part...

Page 23: ...EEN 6 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plugged in or turned on 7 Move choke lever located on engine to START position NOTE D...

Page 24: ...ctor switch is turned to the GAS position the indicator light will become RED up to 4 minutes before goes off Starting the engine successfully during these 4 minutes will turn the indicator light GREE...

Page 25: ...g the engine successfully during these 4 minutes will turn the indicator light GREEN 6 Disconnect all electrical loads from the generator Never start or stop the generator with electrical devices plug...

Page 26: ...do not exceed the maximum wattage rating of the generator when using one or more receptacles Also do not exceed the amperage rating of any one receptacle Do not apply heavy electrical load during bre...

Page 27: ...STARTED DURING BATTERY POWER SAVING MODE UNLESS THE FUEL SELECTOR SWITCH IS TURNED TO THE OFF POSITION AND THEN TURNED BACK TO THE GAS OR LPG POSITION Unwanted Shutdown The generator cannot be started...

Page 28: ...ufficient fuel flow to the engine This is not an indication of a problem with the generator but only a problem with the flow of gas from the LPG cylinder If generator performance seems to be deteriora...

Page 29: ...hart above Notice Once a year you should clean or replace the spark plug and replace the air filter New spark plugs and clean air filter assure proper fuel air mixture and help your engine run better...

Page 30: ...o cause skin cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water a Drain oil by removing the drain plug and the oil filler cap while the engine is warm Change engine...

Page 31: ...ank causing a fire resulting in death or serious injury and or property Contact with muffler area could cause burns resulting in serious injury WARNING A B A Spark plug B Spark plug cap c DO NOT touch...

Page 32: ...and attach with the screws Spark arrester screen Flange Screw Battery Replacement 1 Remove the spark plug wire from spark plug 2 Remove the nut and bolt from the negative and positive posts 3 Loosen...

Page 33: ...il it stops from lack of gasoline This will dry out all remaining gasoline in tank fuel lines and carburetor 5 Turn fuel selector switch to OFF position Fully close the LPG cylinder knob if it is open...

Page 34: ...tic battery charging circuit The battery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is used on a regular basis about once every two...

Page 35: ...esh gasoline 7 Connect wire to spark plug 8 Replace spark plug 9 Drain gas tank and carburetor fill with fresh gasoline 10 Wait 5 minutes and re crank engine 11 Contact authorized service facility 12...

Page 36: ...Page 33 PARTS DIAGRAM AND PART LIST H05753 PARTS DIAGRAM English Customer Service 1 844 FIRMAN1 142 143...

Page 37: ...Page 34 439cc DUAL FUEL ENGINE PARTS DIAGRAM English Customer Service 1 844 FIRMAN1...

Page 38: ...1 1 1 1 1 7 1 1 1 1 2 2 2 1 1 8 2 2 1 FIRMAN 439cc Dual Fuel Engine NO Part Number Qty Description 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104...

Page 39: ...case Comp Bolt drain Washer drain Bolt Oil Level Sensor Flg Bolt M6 15 Bearing Locating Pins Bearing Balance Shaft Camshaft Comp Crankshaft Gear Crank Shaft Gear Drive Gskt Crankcase Cover Oil Dipstic...

Page 40: ...by this warranty Normal Wear Your product needs periodic parts and service to perform well This warranty does not cover repair when normal use has exhausted the life of a part or the equipment as a w...

Page 41: ...f God and other force majeure events beyond the manufacturer s control problems caused by parts that are not original FIRMAN parts units used for prime power in place of existing utility power where u...

Page 42: ...failure under warranty of any warranted part MANUFACTURER S WARRANTY COVERAGE The exhaust and evaporative emissions control system on your is warranted for two years If any emissions related part on y...

Page 43: ...ld Air cleaner 5 Crankcase breather assembly including Breather connection tube 6 Fuel tank evaporative emission control system including Purge valves Carbon canister Vapor hoses and fitting clamps FI...

Page 44: ...P N 357745483 Rev 04 Firman Power Equipment Inc Peoria AZ 85381 www firmanpowerequipment com 8716 West Ludlow Dr Suite 6...

Reviews: