NOTE:
Total power drawn from all receptacles must not exceed the name plate rating.
Engine Start Switch
– Used to start engine
from the starter motor(Electric start model
only). To start engine, press and hold the
switch in the “
START
”(
ll
) position, the
engine will crank and attempt to start. When
the engine starts, release the switch to the
“
RUN
”(
l
) position.
Control Panel
English Customer Service: 1-844-FIRMAN1
1
3-1 Data-Minder(Multi-Meter) –
Push the
SELECT
button to show the Voltage, Hertz
and running hours.
5
6
120V, 30A Twist-Lock
(NEMA L5-30R)
–
Maximum full load 30 Amp current may be
drawn from this 120 Volt receptacle.
7
8
Indicator Light
When the fuel selector switch is turned to the
“
GAS”
or “
LPG”
position, the indicator light will
become
RED
up to
4 minutes
(before goes off).
Starting the engine successfully during these
4 minutes
will turn the indicator light
GREEN
.
MUST HAVE
SOLID RED INDICATOR LIGHT
TO BE ABLE TO START THE GENERATOR. THE
GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE
UNLESS
THE FUEL SELECTOR SWITCH IS TURNED TO
THE “
OFF
” POSITION AND THEN TURNED
BACK TO THE “
GAS
” OR “
LPG
” POSITION.
See
Indicator light
-
Battery power Saving
Mode
section for more information.
3
4
2
1
5
5
6
7
8
9
10
120V, 20A Duplex
– (NEMA 5-20R)
This receptacle is rated so that a total of 20 amps
may be drawn regardless of whether both halves or
just one receptacle is used.
Ground Terminal
– Consult an electrician
for local grounding regulations.
Fuel Selector Switch –
Use to select and turn
on gasoline or LPG fuel source. Fuel (gasoline)
valve is closed when the switch is on “
OFF
” or
“
LPG
” positions. Engine switch is on when the
switch is on “
GAS
” or “
LPG
” positions.
11