NOTE:

If this will be a single-station heat alarm, cover yellow wire with
electrical tape and tuck into junction box.

8.

Lift open battery pocket door. 

9 .

Connect  new  9-volt  battery  to  battery  connector  inside  battery  pocket.
BE  SURE  BAT T E RY  IS  SECURELY
CONNECTED.  Heat  alarm  may  beep
briefly when battery is installed.

1 0 . Close battery pocket door, snapping it

into place. (For tamper- resist, use
long-nosed pliers to remove thin
plastic from notch on heat alarm edge.)

11. Attach connector plug to pins on back

of heat alarm. Plug will only fit one way
and will snap into place.

12. Gently tug connector to be sure

it is attached securely. 

13. Position heat alarm to mounting

plate and turn clockwise to lock
into place. To engage tamper-
resist feature, insert pin into
notch on edge of heat alarm
after alarm is properly positioned in base. See instruction #10 on the
previous page. NOTE: The tamper-resist pin must be removed to
change the batteries and replaced when done.

N O T E :

Heat alarm will not mount to plate if battery is not installed.

14. Turn on power at main fuse box or circuit breaker.

15. Test heat alarm. See TESTING THE HEAT ALARM.

INTERCONNECTING HEAT ALARMS

• This heat alarm is interconnectable to a maximum of 18 alarms, no more

than 12 of which can be smoke alarms. This alarm can be interconnect-
ed only with Firex devices. It is interconnectable with Firex models ADH
(5700 Series), G-6 (406 Series), G-18 (418 Series), PG (484 Series), ADC
(4518 Series), FADC (4618 / 5000 Series), TPCI (4671 Series), COE
(10000 Series), COEA (10400 Series), FADCM (12000 Series), and GCM
(12400 Series). It is NOT interconnectable with the Firex model FXW-R
(428 Series).

• Connect heat alarms to a single AC branch circuit. If local codes do not

p e rmit, be sure the neutral wire is common to both phases.

RED AND GREEN LED INDICATORS

This heat alarm features separate red and green LED indicators. The LEDs
indicate the following:

GREEN LED

Constant on — AC power is present.
OFF — AC power is not present.

RED LED 

can be seen through the Push-to-Test button.

Blinks once a minute — indicates presence of a working battery.

Blinks once a second — heat alarm senses heat and simultaneously

sounds an audible alarm.

OFF — DC power is not present.

OFF and unit is sounding alarm — An interconnected smoke/heat alarm in

the network has sensed smoke or heat.

TESTING THE HEAT ALARM

W A  R  N  I  N G

• Test each heat alarm and smoke alarm in the network to be sure it is

installed correctly and operating properly. 

• Stand at arm’s length from the heat alarm when testing. The alarm horn

is loud to alert you to an emergency and can be harmful to hearing.

• Test heat alarms weekly and upon returning from vacation or when no

one has been in the household for several days.

Test all heat alarms weekly by doing the following:

1. Observe the green LED. A constant green light indicates the heat alarm

is receiving 120V AC power.

2. Firmly depress the Push-to-Test button for at least five (5) seconds. The

heat alarm will sound a loud beep about 4 times a second. The alarm
may sound for up to 10 seconds after releasing the Push-to-Test but-
ton. 

NOTE: 

If heat alarms are interconnected, all heat alarms should

Insert pin here

5

!

Remove thin plastic 

from notch

Summary of Contents for ADH

Page 1: ...ockout heat alarm will not attach to the mounting bracket if a battery is not in the battery pocket Improperly connected or weak battery signal heat alarm will sound a shortbeep once a minute if the battery is weak or improperly connected Green LED indicates that the heat alarm is receiving AC power working under normal operation or in alarm Loud alarm horn 85 decibels at 3 meters 10 feet sounds t...

Page 2: ...T Heat alarms give an audible warning when the temperature at the alarm reaches 58 C 135 F Heat alarms are ideal for kitchens garages base ments boilers rooms attics and other areas where there are normally high levels of fumes smoke or dust which are also areas where smoke alarms should not be installed due to risk of false nuisance alarms For your information the National Fire Protection Associa...

Page 3: ...arning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A heat detector installed in each separate sleeping area in the vicinity but outside the bedrooms and heat or smoke alarms in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms basements and attached g...

Page 4: ...nnect wire location shall be in accordance with NEC Article 300 3b THIS HEAT ALARM SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION S STANDARD 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 Install heat alarm on a 10 cm 4 inch octagon or single gang junction box only 1 From back of heat alarm remove mounting plate To deter a person from tam...

Page 5: ...OE 10000 Series COEA 10400 Series FADCM 12000 Series and GCM 12400 Series It is NOT interconnectable with the Firex model FXW R 428 Series Connect heat alarms to a single AC branch circuit If local codes do not permit be sure the neutral wire is common to both phases RED AND GREEN LED INDICATORS This heat alarm features separate red and green LED indicators The LEDs indicate the following GREEN LE...

Page 6: ...attery from pocket Disconnect and discard drained battery from battery connector 7 Connect a fresh 9 volt battery to connector The battery will fit only one way Be sure battery connector is securely attached to battery terminals 8 Place battery into battery pocket 9 Close battery pocket door Push down until it snaps into place 10 Replace connector plug Connector will snap into place Gently tug con...

Page 7: ...at main fuse box or cir cuit breaker before taking trouble shooting action WARNING DO NOT disconnect battery or AC power to quiet an unwanted alarm This will remove your protection Fan the air or open a win dow to remove heat or dust PROBLEM SOLUTION Heat alarm does not 1 Check that AC power is sound when tested turned on 2 Tu rnoff power Remove heat alarm from mounting plate mounting plate and a ...

Page 8: ...ARRANTIES OF MERCHANTABILITY AND FIT NESS FOR A PARTICULAR PURPOSE ARE LIMITED TO A PERIOD OF FIVE 5 YEARS FROM PURCHASE DATE Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you IN NO CASE SHALL INVENSYS CONTROLS BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY EXPRESS OR IMPLIED WHAT...

Page 9: ... fixé au support de fixation si le compartiment de pile est vide Signal de pile faible ou de mauvaise connexion Le détecteur de chaleur émettra un bip court une fois par minute pour signaler que la pile est faible ou mal installée Le voyant DEL vert indique que le détecteur de chaleur reçoit du courant alternatif fonctionne normalement ou est en alerte L avertisseur sonore 85 décibels à 3 mètres 1...

Page 10: ...ies et leurs biens De plus le détecteur de chaleur peut cesser de fonctionner à n importe quel moment EMPLACEMENT DES DÉTECTEURS DE CHALEUR Les détecteurs de chaleur émettent un avertissement audible lorsque la température atteint 58 C 135 F au niveau du détecteur Les détecteurs de chaleur sont idéals pour les cuisines les garages les sous sols les chaufferies les greniers et tout autre endroit où...

Page 11: ...haleur dans chaque aire séparée de couchage à proximité mais à l extérieur des chambres à coucher et des détecteurs de fumée et de chaleur dans le salon la salle à manger les chambres la cuisine l entrée le grenier la salle de la chaudière les placards les pièces de stockage la buanderie le sous sol et le garage 3 INSTALLATION DE DÉTECTEUR DE FUMÉE Installez un détecteur de chaleur le plus près po...

Page 12: ...eut s appliquer L emplacement du câblage d inter connexion doit être conforme à l arti cle NEC 300 3b CE DÉTECTEUR DE CHALEUR DOIT ÊTRE INSTALLÉ CONFORMÉMENT À LA RECOMMANDATION 72 DE LA NATIONAL FIRE PROTECTION ASSOCIATION National Fire Protection Association Batterymarch Park Quincy MA 02269 Installez le détecteur de chaleur uniquement sur une boîte de raccordement sim ple ou octogonale de 10 cm...

Page 13: ...s plus de 12 peuvent être des détecteurs de fumée Ce détecteur est compatible avec les modèles de détecteurs de fumée Firex ADH série 5700 G 6 série 406 G 18 série 418 PG série 484 ADC série 4518 FADC séries 4618 5000 TPCI série 4671 COE série 10000 COEA série 10400 FADCM série 12000 et GCM série 12400 Il n est PAS con nectable avec le modèle Firex FXW R série 428 Reliez les détecteurs de chaleur ...

Page 14: ...t de pile faible retentit à raison d une fois par minute même si le détecteur est alimenté en électricité Les piles devraient être remplacées régulièrement même lorsque le détecteur de chaleur est alimenté en élec tricité Pour ce type de détecteur de chaleur utilisez uniquement les piles sui vantes Eveready 522 ou 1222 ou Duracell MN 1604 AVERTISSEMENT N UTILISEZ QUE LES PILES INDIQUÉES DANS CE MA...

Page 15: ...X sorties pour chaque pièce et un chemin d évacuation vers l extérieur à partir de chaque sortie Apprenez à tous les membres du foyer à toucher la porte pour vérifier si elle est brûlante et d utiliser une autre sortie dans ce cas là APPRENEZ LEUR À NE PAS OUVRIR LA PORTE SI ELLE EST BRÛLANTE Apprenez aux membres du foyer à ramper sur le sol pour rester au dessous des fumées des vapeurs et des gaz...

Page 16: ... QUELQUE NATURE QUE CE SOIT MÊME SI LAPERTE OU LE DOMMAGE EST CAUSÉ PAR SA NÉGLIGENCE OU SA FAUTE Certains États ou certaines provinces n autorisentpas l exclusionou la limita tion des dommages accessoires ou indi rects parconséquent la limitation ou l exclusion ci dessus pourraitne pas s appliquerà vous La présentegarantie vous accorde des droits spécifiques reconnus par la loi et vous pourriez a...

Reviews: