3. Mount Anchor Plate: Chimneys for
masonry fireplaces begin with an Anchor Plate.
Important: be sure the surface of the masonry
chimney has a level surface on which to attach
the Anchor plate. If the top of the masonry
does not have a level surface, then you will
need to modify the masonry accordingly.
Center the Anchor plate over the masonry
flue opening, and seal the Anchor Plate with
a high-temperature sealant. Secure Anchor
plate with (4) 2” x 1/4” masonry anchors (Fig.
2).
4. Attach Chimney: Attach the first Chimney
Section onto the Anchor plate by using the
sheet metal screws provided. Always maintain
at least a 2-inch clearance to combustibles.
The 2-inch clearance is an air space; do not
fill that clearance space with any materials. If
an offset is required, refer to the Elbow Offset
Installation Section below.
5. Frame Openings: From the ceiling, drop a
plumb bob to the center of the fireplace’s flue
outlet and mark this center point on the ceiling.
Mark appropriate cutting lines around the
center point. Cut a square hole in the ceiling.
Frame a level, square opening centered over
the hole that you have cut. Frame openings at
each floor level above the Fireplace (Fig 3).
These openings are to hold the Firestop and
Attic Insulation Shield. Locate each opening by
dropping a plumb bob to the four corners of the
opening below. Maintain the minimum 2-inch
clearance/air-space. Maintain the minimum
Table 1
Diameter
Framing Dimension
10"
17" x 17"
12"
19" x 19"
14"
21" x 21"
16"
23" x 23"
Figure 2
MASONRY
ANCHORS
HI-TEMP
SEALANT
FIREPLACE
ANCHOR PLATE
FIRESTOP
SQUARE FRAME
CHIMNEY
FIRESTOP
ATTIC INSULATION
CHIMNEY SECTION
CHASE TOP
STORM
TERMINATION
SHIELD & COLLAR
CAP
COLLAR
SQUARE FRAME
FLASHING
(4) ROOF
RADIATION
SHIELDS
Figure 3
105
Summary of Contents for 3620 Avenue C
Page 20: ......
Page 21: ...21 PRODUCT PAGES...
Page 29: ...29 FireRock Specifications Approved for Indoor Outdoor Use 48 Conventional FR0048...
Page 35: ...35 FireRock Specifications 30 Rumford FR0530 Approved for Indoor Outdoor Use...
Page 37: ...37 FireRock Specifications Approved for Indoor Outdoor Use 36 Rumford FR0536...
Page 39: ...39 FireRock Specifications Approved for Indoor Outdoor Use 42 Rumford FR0542...
Page 41: ...41 FireRock Specifications Approved for Indoor Outdoor Use 48 Rumford FR0548...
Page 51: ...51 FireRock Specifications Approved for Indoor Outdoor Use 30 Vent Free FR0230...
Page 53: ...53 FireRock Specifications Approved for Indoor Outdoor Use 36 Vent Free FR0236...
Page 55: ...55 FireRock Specifications Approved for Indoor Outdoor Use 42 Vent Free FR0242...
Page 57: ...57 FireRock Specifications Approved for Indoor Outdoor Use 48 Vent Free FR0248...
Page 59: ...59 FireRock Specifications Approved for Indoor Outdoor Use 30 Vent Free Lite FR0630...
Page 61: ...61 FireRock Specifications Approved for Indoor Outdoor Use 36 Vent Free Lite FR0636...
Page 63: ...63 FireRock Specifications Approved for Indoor Outdoor Use 42 Vent Free Lite FR0642...
Page 65: ...65 FireRock Specifications Approved for Indoor Outdoor Use 48 Vent Free Lite FR0648...
Page 67: ...67 FireRock Specifications Approved for Outdoor Use Only 30 Outdoor Conventional FR0730...
Page 69: ...69 FireRock Specifications Approved for Outdoor Use Only 36 Outdoor Conventional FR0736...
Page 73: ...73 FireRock Specifications Approved for Outdoor Use Only 30 Arched Outdoor Conventional FR1230...
Page 75: ...75 FireRock Specifications Approved for Outdoor Use Only 36 Arched Outdoor Conventional FR1236...
Page 77: ...77 FireRock Specifications Approved for Outdoor Use Only 42 Arched Outdoor Conventional FR1242...
Page 83: ...83 FireRock Specifications Approved for Outdoor Use Only FireRing FRRING...
Page 85: ...85 FireRock Specifications Approved for Outdoor Use Only Square Fire Pit FRSQ60...
Page 90: ...90 DURACHIMNEY II AIR COOLED CHIMNEY FOR MASONRY FIREPLACES UL 103...
Page 123: ......
Page 124: ......